IQAN-MD4 Instruction book Publ no HY33-8408-IB/UK Edition 2014-12-10
Contents Contents 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Overview of relevant documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2 Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Read This . . . . . . . . . . . . .
Contents Connecting switches to the voltage inputs using VREF . . . . . . . . . . . . 21 Connecting switches to the voltage inputs using +BAT . . . . . . . . . . . . 22 Directional pulse count input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Connecting a directional pulse count channel (DPCNT) . . . . . . . . . . . . 23 Low-side digital outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 7 Start-up . . . . . . . . . . . . . . . . . . .
Warnings 1 1 Introduction Introduction These instructions are to be used as a reference tool for the vehicle manufacturer’s design, production, and service personnel. The user of these instructions should have basic knowledge in the handling of electronic equipment. Warnings Sections marked with a symbol in the left margin, must be read and understood by everyone using the system, carrying out service work, or making changes to hardware and software.
Overview of relevant documentation 1 Introduction Overview of relevant documentation The following publications are relevant for users of this product. The main documentation contains information that is not found elsewhere. The additional documentation contains product information in a compact format, for details on the information found in those documents, consult this manual.
Read This 2 2 Precautions Precautions Work on the hydraulics control electronics may only be carried out by trained personnel who are well-acquainted with the control system, the machine and its safety regulations. WARNING Make sure that you have sufficient knowledge before designing, modifiying or servicing the control system. Read the relevant sections of this document before conducting any work on the control system. WARNING This product is not field repairable.
Read This 2 Precautions Start-up, maintenance, and diagnostics For all personnel carrying out installation, commissioning, maintenance or troubleshooting. WARNING Work on the hydraulics control electronics may only be carried out by trained personnel who are well-acquainted with the control system, the machine and its safety regulations. Before you start, Read section "Start-up". Additional information for service Mounting and maintenance instruction book.
IQAN-MD4 3 3 Product description Product description IQAN-MD4 The IQAN-MD4 is a family of combined display and bus master modules capable of running applications created by IQANdesign software. Built on a 32-bit platform the units have large computational power and is capable of controlling large applications. The IQAN-MD4 module. System overview The master module, IQAN-MD4, is the central unit in the system, or in the case of a multi-master system, one of the central units.
I/O 3 Product description I/O +BAT CAN-H -BAT CAN-L +RTC CAN-H +VREF MD4 CAN-L CAN-H CAN-L ETHERNET PORT 0 CAN-H CAN-L PORT 1 Voltage inputs The IQAN-MD4 module has two (2) voltage inputs VIN-A andVIN-B for connection of 0-5 Vdc signals. These inputs can be configured as digital inputs for reading switches. Voltage inputs and digital inputs share positions, see below.
Communication 3 Product description Communication The communication interfaces are used for uploading/downloading applications, connecting to expansion modules, connecting to cameras or diagnostics. CAN related functions The IQAN-MD4 uses a CAN-bus (CAN = Controller Area Network) to communicate with IQAN expansion modules and other systems. The CAN-bus is a robust communication protocol that is widely used and well proven within the automotive industry. The unit has four (4) CAN buses, CAN-A thru CAN-D.
Internal diagnostics 4 4 Safety Safety Internal diagnostics The module performs a number of self-checks that improve safety. Checks include monitoring of voltage supplies, checksums on memory and a watchdog that monitors software execution. The module is using a real time operating system which supervises software execution. If a critical error is detected, the module is stopped, with CAN-bus and outputs off. CAN-bus interruption The IQAN modules communicate on a CAN-bus.
Mounting the module 5 5 Mounting Mounting Mounting the module The IQAN module should be mounted according to the following instructions: Dashboard or panel assembly When installing in a dash or panel the recommended panel thickness is 1.0 - 3.5 mm. Use M4 screws to attach the supplied steel clips.. Panel mounting the IQAN-MD4 Ball or tilt/swivel mount The option to use ball mounting or tilt swivel mounting for display position flexibility is made possible by using Parker’s aluminum bracket.
Mounting the module 5 Mounting Mounting considerations N OTICE IQAN-MD4 shall be positioned in the machine per the following instructions: • The unit is designed for outdoor use. Position the unit in desired location and make sure that it is not exposed to mechanical damage. • The connectors on the reverse side of the unit should be accessible. • Position the unit so there is no risk that the cabling can be folded, crushed, worn or damaged in any way.
Connector C1 and C2 6 6 Installation Installation Connector C1 and C2 Connector kit Parker 20073081 C1 (DTM12 key A) Housing C1 Deutsch no. DTM06-12SA Pin type Deutsch no. 1062-20-0222 Wedge type Deutsch no. WM12S Sealing plug Deutsch no. 0413-204-2005 1 2 3 4 12 11 10 9 5 8 6 7 C2 (DTM12 key B) Housing C2 Deutsch no. DTM06-12SB Pin type Deutsch no. 1062-20-0222 Wedge type Deutsch no. WM12S Sealing plug Deutsch no. 0413-204-2005 Recommended cable 0.
Connector C1 and C2 6 Installation Connector C1 pin assignments Pin No. Symbol Function C1:1 -BAT Power supply C1:2 CANL-A CAN low voltage bus line C1:3 CANL-B CAN low voltage bus line C1:4 CANL-C CAN low voltage bus line C1:5 CANL-D CAN low voltage bus line C1:6 ADDR-L Low side to address tag. Return (0V) C1:7 ADDR-H High side to address tag.
Connector C1 and C2 6 Installation Connector C3 and C4 Connector kit Parker N/A Recommended cable 20077780 M12 4pin D-code Industrial Ethernet Connector C3 and C4 pin assignments Pin No.
Supply voltage Supply voltage Before any installation of the IQAN system can take place, make sure the ignition lock is turned off and the battery is disconnected. Emergency stop Make sure an Emergency Stop disconnecting the power supply, is easily accessible at any time. The figure below shows how to connect the emergency stop. Connecting of Supply Voltage The supply voltage, should be within the operating interval, see Appendix A. Connect the supply voltage to +BAT and -BAT.
Addressing Addressing IQAN-MD4 use of an ID-Tag In IQANdesign 3.0 and higher software, more than one IQAN master module can be used together in a multi-master system. The master modules are each given a unique address by using an ID-Tag. The value of the ID-Tag identifies the master and will enable a single project application to be loaded into more than one master module over the CAN bus. The functionality needed for each master is loaded based on the ID-tag address.
Diagnostic interfaces Diagnostic interfaces IQAN software includes many tools for tuning, measuring, accessing logs and otherwise checking the performance or troubleshooting your control system. To use the diagnostic tools with an IQAN master module you may choose between different ways to connect to the unit. CAN diagnostics connection One of the CAN buses of the IQAN master module may be dedicated for diagnostics.
Video input Ethernet diagnostics communication The "A" (C3) Ethernet port is used for diagnostic communication or uploading and downloading project files using IQANdesign/IQANrun. On port A, the IP address is automatically assigned using DHCP. It is recommended to use an environmentally sealed panel mounted RJ45 connector for easy access. Parker part number 20077785. Video input The IQAN MD4 master modules are capable of showing video inputs from an external source.
Video input Analog Cameras It is also possible to connect an analog camera by routing the video feed through a video server with ethernet connection. In this case, it is the video server that needs to have the correct IP address set.
Reference voltage, VREF Reference voltage, VREF The IQAN module is internally equipped with a voltage regulator to generate the reference voltage VREF. The standard reference voltage will feed different kinds of sensors and potentiometers. On the IQAN-MD4 there is no -VREF pin, instead the -BAT is used as -VREF. To get the best result, connect as close to the connector as possible to minimise voltage fluctuations. In connection examples that follow, -VREF will refer to the -BAT pin.
Voltage inputs Voltage inputs Connecting sensors to the voltage inputs The sensor signal range must be 0-5 Vdc. To detect signal errors such as short circuits or interruptions the active signal range be within 0.5-4.5 Vdc. [V] 5 Error detection range Active signal range Error detection range 0 t Active signal range. The current consumption related to the voltage input is negligible.
Voltage inputs Connecting a 2-wire temperature sensor to voltage in When you connect a PTC (positive temperature coefficient) temperature sensor you may need to use a pull up resistor on the input signal. Please check the technical data for your specific temperature sensor. EXAMPLE Connect the negative terminal of the temperature sensor to -VREF, and the signal to VIN-X. The pull up resistor will be connected between VIN-X, and +VREF.
Voltage inputs Connecting switches to the voltage inputs using +BAT It is recommended to connect system voltage +BAT to the input through a switch in order to reserve 5Vdc VREF for sensors and potentiometers. EXAMPLE Connect the positive and negative terminals of the switch to supply or the unit’s +BAT, and DIN-X, respectively. +BAT IQAN module DIN-X switch Connecting a switch to DIN-X and +BAT.
Directional pulse count input Directional pulse count input Connecting a directional pulse count channel (DPCNT) The DPCNT is a physical analog input. The directional pulse count input channel is used to count pulses. It is bi-directional, which means it can add and subtract pulses. The DPCNT is primarily designed for input from an encoder wheel. For maximum frequency, see Appendix A.
Low-side digital outputs Low-side digital outputs The low-side digital outputs are designed to drive small loads, e.g. lamps and buzzers. Low-side digital outputs work by grounding a signal through the module. See Appendix A for maximum loads per output. EXAMPLE Connect the lamp to the low-side digital outputs using a DOUT(LS) position, and the +BAT, as supply. +BAT IQAN module load DOUT(LS)-X Connecting a switch to DOUT(LS)-X and +BAT.
Start-up procedures 7 7 Start-up Start-up Start-up procedures This chapter contains instructions for action to be taken in connection with the initial start. WARNING Risk of injury! If the control system is not fitted properly, the machine could move uncontrollably. The machine’s engine shall not be started before the control system is completely fitted and its signals are verified.
IQAN-MD4 Technical Overview Appendix A Appendix A IQAN-MD4 Technical Overview Absolute Maximum Ratingsa Ambient temperature -30 to 70 °C Storage temperature -40 to 85 °C Voltage supply on +BAT 6.5 to 36 V Reverse polarity protection on +BAT 36 V with external 20A fuse (recommended fuse 3A to 5A) Voltage on any pin with respect to -BAT 36 V a.The “Absolute Maximum Ratings” table lists the maximum limits to which the device can be subjected without damage.
IQAN-MD4 Technical Overview Appendix A System TA = -30 to +70 °C, unless otherwise specified Weight MD4-7 MD4-5 930g 670g Ambient temperature, TROC -30 to 70 °C Voltage supply on +BAT, VBAT 9 to 32 V Current supply VBAT = 14V VBAT = 28V 600 mA 300 mA Current supply RTC VBAT = 14V VBAT = 28V RTC backup time 1.7 mA 3.7 mA 14 days, VBAT=0, VRTC=0, TA=+25 °C (7 days TA = -30 to +70 °C) Start-up time Embedded functions HMI running 1.7 s (typical) 4.
IQAN-MD4 Technical Overview Appendix A Sensor supply - VREF Number of VREF 1 Output voltage 5 V ±150 mV, -30 to 70 °C Output voltage temperature drift 0.50 mV/°C Maximum load current 50 mA Protection over load, SCB, SCG Diagnostics over/under voltage Under/over voltage threshold ±150 mV from nominal value Signal input - VIN Number of VIN 2 (configuration may reduce number) VIN full scale 5000 mV ±100 mV VIN resolution 12 bits = 1.
IQAN-MD4 Technical Overview Appendix A Power driver - DOUT Number of DOUT low-side 4 (configuration may reduce number) Maximum load Single channel All channels 300 mA 850 mA Minimum load 2 mA Leakage current in OFF state <200 µA Protection over load, SCB, SCG Diagnostics Operational ON Operational OFF over load open load CAN Number of CAN buses 4 (depends on variant) CAN specification 2.0A and 2.
Error messages and actions Appendix B Appendix B Error messages and actions If a fault is detected, a message will be presented on the display. WARNING An error message could indicate that a hazardous situation exists. If precautions are not taken, this could result in death, serious injury or major property damage. Failure Modes The following tables contain information about the different possible failures that could occur for each module subsystem.
Failure Modes Appendix B Failure modes for VREF Failure mode Effect 1 +VREF Open VIN out of range, will create a VIN error => VIN=Predefined error value. 2 -VREF Open VIN out of range, will create a VIN error => VIN=Predefined error value. 3 +VREF Short-circuit to -VREF VREF error => VIN out of range, will create a VIN error => VIN=Predefined error value. 4 +VREF Short-circuited to +BAT VREF error => VIN out of range, will create a VIN error => VIN=Predefined error value.
Dimensioning of the IQAN-MD4-7 Appendix C Appendix C 182 160 194 153,4 M4x10 (4x) Dimensioning of the IQAN-MD4-7 18 92,4 133 48 5,5 121 units=mm 183 min.
Dimensioning of the IQAN-MD4-5 Appendix C M4x10 (4x) 152 130 164 115 Dimensioning of the IQAN-MD4-5 18 86,2 133 48 5,5 121 units=mm 153 min.
For latest information visit our website www.iqan.com Parker Hannifin Electronic Controls Division SE-435 35 Mölnlycke Sweden Tel +46 31 750 44 00 Fax +46 31 750 44 21 www.parker.com/ecd Information in this instructionbook is subject to change without notice Parker Hannifin Electronic Controls Division 1651 N.