.2 MOTOR HORSEPOWER SELECTION (J2) –
S
et Jumper
J
2 to the corresponding position for the motor being used.
S
ee Figure 18.
6
.3 AUTOMATIC RIDE-THROUGH OR MANUAL RESTART
SELECTION (J3) –
Jumper J3 is factory set to the “A” posi-
tion for Automatic Ride-Through. If the power is interrupted
for up to 2 seconds, the drive will shut down and then
“ride-through” and automatically return to the set frequency.
If Jumper J3 is set to the “M” position, the drive will have to
be manually restarted for a momentary power loss using the Start/Stop Switch. See Figure 19. Also
see Section 11.2, on page 22, for the Status (ST) LED indication.
6.4 60 Hz AND 50 Hz MOTOR
OPERATION AND DRIVE
OUTPUT FREQUENCY
SELECTION (J4 AND J5) –
Both jumpers must be set for
the appropriate motor name-
plate frequency rating.
6.4.1 SETTING THE DRIVE
FOR 60 Hz OR 50 Hz
MOTOR OPERATION –
The drive is factory set
to operate 60 Hz
motors. Jumper J4 is
factory set to the “1X”
position and Jumper J5
is factory set to the “60Hz” position. For
50 Hz motors, set Jumper J5 to the
“50Hz” position, and be sure Jumper J4
is set to the “1X” position. See Figure 20.
6.4.2 SETTING THE DRIVE FOR TWO TIMES
THE RATED MOTOR RPM –
The drive
can also be used to operate the motor up
to two times the rated RPM. However,
constant horsepower will result when
operating the drive in the “2X” mode
above the motor rated frequency.
See Figure 21, on page 18.
For 120 Hz output with 60 Hz
motor, set Jumper J4 to the
“2X” position and be sure
Jumper J5 is set to the “60Hz”
position. For 100 Hz output with
50 Hz motor, set Jumper J4 to
the “2X” position and set
Jumper J5 to the “50Hz” posi-
tion. See Figure 22, on page 18.
17
F
IGURE 17 – REMOVING JUMPER J1
O
N CATALOG NOS. ID5601, ID5602
FIGURE 18 – MOTOR HORSEPOWER SELECTION
T
erminal
Installed
Removed
Terminal
FIGURE 19 – AUTOMATIC RIDE-THROUGH
OR MANUAL RESTART SELECTION
Automatic Ride-Through
(Factory Setting)
(J3 Installed in “A” Position)
Manual Restart
(J3 Installed in “M” Position)
A
J3
M
A
J3
M
J2
C
atalog No.
ID5601
C
atalog No.
ID5602
1 2**
3/4 1
1
⁄2**
1/2 1
1/4 3/4
1/8 1/2
C
atalog No.
ID5203*
C
atalog No.
ID5403*
C
atalog No.
ID5405*
3*** 3 5
2*** 2 3
1
1
⁄2 1
1
⁄2 2
1 1 1
1
⁄2
3/4 3/4 1
A
B
C
D
E
The factory setting is shown in bold.
*Jumper J2 on Catalog Nos. ID5203, ID5403, ID5405 is labeled “A”, “B”, “C”, “D”, “E”.
**Catalog No. ID5602 is rated 1
1
⁄2 HP maximum with 115 Volt AC line input and 2 HP
maximum with 208/230 Volt AC line input. ***Catalog No. ID5203 is rated 2 HP maximum
with single-phase AC line input and 3 HP maximum with 3-phase AC line input.
FIGURE 20
60 Hz & 50 Hz MOTOR SELECTION
60 Hz Motor Operation
(Factory Setting)
(J4 Installed in “1X” Position)
(J5 Installed in
“60Hz”
Position)
50 Hz Motor Operation
(J4 Installed in “1X” Position)
(J5 Installed in
“50Hz”
Position)
2X
J4
1X
50Hz
J5
60Hz
2X
J4
1X
50Hz
J5
60Hz