Specifications

A B C D E
10
Description Specification Factory Setting
1
15 Volt AC Line Input Voltage Operating Range (Volts AC)
1
15 (±15%)
208/230 Volt AC Line Input Voltage Operating Range (Volts AC) 208 (-15%) / 230 (+15%)
4
00/460 Volt AC Line Input Voltage Operating Range (Volts AC)
3
80 (-15%) – 460 (+15%)
Maximum Load (% Current Overload for 2 Minutes) 150
C
arrier, Switching Frequency (kHz)
1
6, 8
Signal Following Input Voltage Range
1
(Volts DC)
0 – 5
Output Frequency Resolution (Bits, Hz) 10, .06
Minimum Speed Trimpot (MIN) Range (% Frequency Setting) 0 – 40 0
Maximum Speed Trimpot (MAX) Range (% Frequency Setting) 70 – 110 100
Acceleration Trimpot (ACCEL) and Deceleration Trimpot (DECEL) Range (Seconds) .3 – 20 1.5
B
oost Trimpot (BOOST) Range (Volts/Hz)
0
30
5
Slip Compensation Trimpot (COMP) Range at Drive Rating (Volts/Hz) 0 – 3 1.5
C
urrent Limit Trimpot (CL) Range (% Full Load)
4
0 – 200
1
60
Jog Trimpot (JOG) Range (% Frequency Setting) 0 – 100 35
M
otor Frequency Setting (Hz) (Jumper J5)
5
0, 60
6
0
Output Frequency Multiplier (1X, 2X) (Jumper J4)
2
1, 2 1
Minimum Operating Frequency at Motor (Hz) 1
Speed Range (Ratio) 60:1
Speed Regulation (30:1 Speed Range, 0 – Full Load) (% Base Speed)
3
2.5
Overload Protector Trip Time for Stalled Motor (Seconds) 6
Undervoltage/Overvoltage Trip Points for 115 Volt AC Line Input (± 5%) (Volts AC)
4
76 – 141
Undervoltage/Overvoltage Trip Points for 208/230 Volt AC Line Input (± 5%) (Volts AC)
4
151 – 282
Undervoltage/Overvoltage Trip Points for 400/460 Volt AC Line Input (± 5%) (Volts AC)
4
302 – 567
Run/Fault Relay Output Contact Rating (Amps at 30 Volts DC, 125 Volts AC, 250 Volts AC) 1, 0.5, 0.25
Operating Temperature Range (°C / °F) 0 – 45 / 32 – 113
TABLE 3 – GENERAL PERFORMANCE SPECIFICATIONS
TABLE 4 – ELECTRICAL RATINGS
Notes: 1. Requires an isolated signal. If a non-isolated signal is used, or if using 0 to ±2.5 thru 0 to ±25 Volts DC, or 4 – 20 mA DC signal input,
install the ID5SI-2 Signal Isolator. 2. Allows the motor to operate up to two times the rated RPM. Constant horsepower will result when operating the
drive in the “X2” mode above the motor rated frequency.
3. Dependent on motor performance. 4. Do not operate the drive outside the specified AC line
input voltage operating range.
Catalog No.
AC Line Input
Fuse or
Circuit
Breaker
Rating
(Amps)
Drive Output
Motor Horsepower
Selection
2
(Jumper J2)
Net Wt.
Volts AC
(50/60 Hz)
Phase
(φ)
Maximum
Current
(Amps AC)
Voltage
Range
(Nominal)
(Volts AC)
Maximum
Continuous
Load Current
(RMS Amps/Phase)
Maximum
Horsepower
(HP (kW))
Black
White
1
lbs kg
ID5601-BO ID5601-WO
115 1 16 20 0 – 230
3.6 1 (.75) 1 3/4 1/2 1/4 1/8 5.9 2.7
208/230 1 10 15 0 – 230
ID5602-BO ID5602-WO
115 1 22 25 0 – 230 5.5 1
1
2 (1.13)
1
1
2
4
1 3/4 1/2 10.3 4.7
208/230 1 15 20 0 – 230 6.7 2 (1.5)
2
4
ID5203-BO ID5203-WO 208/230
1 15 20 0 – 230 6.7 2 (1.5)
2
5
1
1
2 1 3/4 10.3 4.7
3 10.8 15 0 – 230 9.0 3 (2.25)
3
5
ID5403-BO
3
ID5403-WO
3
400/600 3 5.3 10 0 – 400/460 4.6 3 (2.25) 3 2 1
1
2 1 3/4 10.3 4.7
ID5405-BO
3
ID5405-WO
3
400/600 3 9.6 10 0 – 400/460 8.3 5 (3.75) 5 3 2 1
1
2 1 10.3 4.7
Notes: 1. White FDA approved finish. 2. Bold indicates factory setting. Jumper J2 on Catalog No. ID5601 is labeled “1”, “3/4”, “1/2”, “1/4”, “1/8” (fac-
tory set to the “1” position). Jumper J2 on Catalog No. ID5602 is labeled “2”, “1
1
2”, “1”, “3/4”, “1/2” (factory set to the “1
1
2” position). Jumper J2 on
Catalog Nos. ID5203, ID5403, ID5405 is labeled “A”, “B”, “C”, “D”, “E” (factory set according to the table). 3. Catalog Nos. ID5403, ID5405 are rated
0 – 400 Volts AC for 50 Hz motor operation and 0 – 460 Volts AC for 60 Hz motor operation.
4. Catalog No. ID5602 is rated 1
1
2 HP maximum with 115
Volt AC line input and 2 HP maximum with 208/230 Volt AC line input.
5. Catalog No. ID5203 is rated 2 HP maximum with single-phase AC line input
and 3 HP maximum with 3-phase
AC line input.