Specifications

4-4 Setup and Operation MN715P
Potentiometers P1 - P6 (270° of rotation)
Refer to Figure 4-1 for location of potentiometers.
ACCEL timeP1
The time required to reach the Maximum Frequency
setting of P4. Accelerates at a linear rate.
First half (0 to 135° )= 0.1 sec to 10 sec
last half (135 - 270°) =10sec to 60 sec
10 Sec.
0.1 Sec.
60 Sec.
DECEL timeP2
The time required to ramp to a stop. The voltage
and frequency to the motor are reduced at a linear
rate.
First half (0 to 135° )= 0.1 sec to 10 sec
last half (135 - 265°) =10 sec to 60 sec
(265 - 270°) = Coast - Allows motor to coast to stop.
10 Sec.
0.1 Sec.
60
Sec.
Coast
Minimum frequencyP3
Sets the minimum output frequency to the motor .
This is a percentage of the S1-1 base frequency
setting.
0
1
/
2
F
Base
Maximum frequencyP4
Sets the maximum output frequency to the motor.
This is a percentage of the S1-2 frequency limit
setting.
1
/
2
LIM
LIM
Current LimitP5
50% to 100% of control rated amps.
50%
100%
Torque BoostP6
Increases the nominal motor starting voltage from 0
to 15% to increase starting torque.
0%
15%