1-8 General Information MN1269
Specifications
Standard Chassis & Power Supply Assemblies
Output:
LD2- LD4-
Rated Bus Voltage (VDC) 160 160
Rated Continuous Current (A) 27 50
Positive Logic 15VDC (A) 1.0 1.0
Negative Logic 15VDC (A) 1.0 1.0
Input:
LD2- LD4-
Nominal Bus Input (VAC 50/60Hz) 115 115
Bus Input Range (VAC 50/60Hz) 105-125 105-125
Number of Phases 1 3
Nominal input for Fan & Logic Supply (VAC 50/60Hz) Prewired 115 (1 phase)
Overvoltage Protection:
LD2- LD4-
Continuous Rating (W) 250 500
Peak Rating (W) 4000 8000
Clamp Rating (V) 195 195
Shutdown Point Typical (V) 220 220
General:
LD2- LD4-
Operating Temperature (°C) 0-50 0-50
Weight (lbs.) 14 20.6
Footprint (inches)
Length 9 13
Width 10.5 10.5
Height 7.25 7.25
Notes:
1. An isolation transformer is not required for “LD” controls (115VAC, 1phase).
2. For LD-4, the power requirements cannot be met by 115VAC 1phase input power. It is recommended that a
230VAC input power be used with an isolation transformer to provide 115VAC 3 phase input power for an LD-4.
3. Line power limitations with 1 phase prevents the chassis and drives from delivering full continuous rated output
power.