5-12 Software Setup
H Series โ€“ Fault Message Description Continued
Fault Code
Fault Message
15H 18H
Fault Description
ยตp Reset 22 22 A software watchdog timer has reset the
processor because a process has timed out.
ROM Fault 23 ROM checksum error.
1 Min Overload 24 24 Peak output current exceeded the 1 minute
rating value.
No I Feedback 25 Loss of current feedback
New Base ID 26 26 Control board detected a change in the Power
Base ID value in software.
EXB Selection 27 27 Expansion board not installed to support the
Level 1 Input Block, Command Select
parameter.
Power module 28 Power module failure.
Coโ€“processor 29 Coโ€“processor error (i.e. DSP board).
Software
Version
30 Wrong control software version detected.
Feedback
Module
31 Feedback HW module failure.
Serial watchdog 32 Serial port transmit/receive error
FLT Network 33 33 Lost network communications.
Hardware
Protect
54 A general hardware fault was detected but
cannot be isolated.
Unknown FLT
Code
55 34 Microprocessor detected a fault that is not
identified in the fault code table.
Bus Current
SENS
56 Failure to sense bus current.