Electric Company Computer Drive User Manual

www.supportme.net
8-4 Specifications MN1942
8.1.5 Digital inputs - drive enable and DIN0 general purpose (X3)
Unit All models
Type Opto-isolated inputs
Input voltage
Nominal
Minimum
Maximum
VDC
24
12
30
Input current (maximum, per input) mA 50
Sampling interval ms 1
Minimum pulse width µs 5
8.1.6 Digital inputs DIN1, DIN2 - high speed general purpose (X3)
Unit All models
Type Opto-isolated inputs
Input voltage
Nominal
Minimum
Maximum
VDC
24
12
30
Input current (maximum, per input) mA 20
Maximum input frequency MHz 1
Minimum pulse width ns 250
8.1.7 Digital outputs DOUT0, DOUT1 - status and general purpose (X3)
Unit All models
User supply (maximum) V 28
Output current (max. continuous) mA 100
Fuse
Approximate trip current
Reset time
mA
s
200
<20
Update interval ms 1