User manual
Copyright © 2000 EIM Company, Inc 13840 Pike Road Missouri City, TX 77489 (281) 499-1561 Page 16
Controlinc Digital Futronic VIII User Manual
Model DF320A Version 1.0
(
2003-01-31
)
6.3. Appendix B … AC Tech Drives (SCF Series)
Programming
VFC drives are programmed at EIM for use with the Futronic VIII system. However, some parameters
may need to be changed for tuning or in the event of drive replacement. The following table lists the
parameters affecting Futronic VIII operation. Refer to the AC Tech manual for instruction on editing
parameters.
Parameter # Description Setting # Value
05 Standard Speed Source 02 Preset Speed #1
10 TB-13A Function Select 05 Run Reverse
11 TB-13B Function Select 04 Preset Speed #2
17 Rotation 02 Forward and Reverse
19 Acceleration Time B ------ 0.1 seconds
20 Deceleration Time B ------ 0.1 seconds
43 Serial Address ------ 247
31 Speed #1 ------ 60 Hz(High Speed)
32 Speed #2 ------ 30 Hz(Low Speed)
12 TB-13C Function Select 09 Accel / Decel (A)
42 Accel / Decel (A) ------ 1 second
Although there are many parameters available for programming in the drive setting these parameters
will get the drive operating with the M2CP. Further tuning can be done with a PC and the AC Tech
Techlink software. Refer to the drive manual when making these adjustments.
Wiring
This model drive is usually mounted in the M2CP enclosure and wired by EIM. However, if the Drive is
remote mounted, connections should be made as indicated in Figure B1.
Figure B1