Installation manual
36
8. Mount the panel.
Dry fit the Panel against the mounting surface to be 
sure there are no high points that need to be removed. 
Clean the mating surfaces and then apply a bead 
of silicone adhesive. Remove the masking from the 
double sided adhesive strips. Carefully push the extra 
6" to 8" of cable into the conduit as you position the 
Panel. Seat the Panel into the silicone, being sure it is 
level or square or parallel with surrounding surfaces. 
Peel backing off adhesive strips. Push the Panel firmly 
against the mounting surface so that the adhesive 
strips grasp firmly to the mounting surface. The 
adhesive strips will hold the Panel in position while the 
silicone cures.
Locating and Installing the Spa-Side Control Center (contâd)
5.  Cut the excess 1" conduit flush with the final 
finished surface.
After all finish work has been completed (plaster, tile, 
coping stone, deck finished, etc.), cut the 1" conduit 
flush with the finished surface. Sawing the conduit 
will not produce a flush surface, so grind, sand, or file 
as necessary. After cutting flush, deburr the inside 
diameter of the conduit.
6. Pull the panel cable through the conduit.
An electrician's fish is required for pulling the wire 
through the conduit. For long pulls, wire lubricant 
is recommended.
Push the fish from the System Control Center to the 
Panel location. After the fish has exited the conduit at 
the Panel location, fasten the cable to the fish. 
With one person pulling the cable and one person at 
the Panel location assuring that no kinks or knots occur, 
pull the cable through the conduit and into the low 
voltage compartment of the System Control Center. 
 ATTENTION: If the cable on the spa panel is not long 
enough to reach the System Control Center, do not add 
length to the cable by splicing additional cable onto 
the cable; obtain a spa panel with a cable that is long 
enough to reach. 
7. Make the final connection.
Route the cable to the top of the printed circuit board to 
the 4-position terminal blocks labeled COM A, 
COM B, and COM C. The panel may be connected to any 
one of these terminal blocks. After allowing for a small 
service loop, cut off the excess cable. Remove 
1â to 2â of the cable jacket and strip 1/4â of the 
insulation off of the four wires. Connect the wires 
to one of the terminal blocks using the following 
wire table.
      POSITION     WIRE COLOR
     9V     RED
     A     GREEN
     B     WHITE OR YELLOW
     GND     BLACK
ADHESIVE STRIPS
SILICONE
SEALANT 
HERE
Fig. 27 Mounting the Spa-Side Control Panel