Operating instructions
Thegaspressureregulatorispartofthecombinationvalveandisadjustedtoyieldapressureof3.5”
watercolumn(9mbar)forNaturalGas.IftheovenisorderedforuseonPropaneGasorButane,the
pressureregulatorinthecombinationvalveispresetatthefactorytoyieldapressureof10”water
column(25mbar).
GassupplypressureintheEuropeanCommunitycountriesshouldbeasbelow.
GasTypeSupplyPressure
G2020mbar
G2525mbar
G20/2520/25mbar
G3030or50mbardependingoncountry
G3130,37,or50mbardependingoncountry
Aseparateshut-offvalveforeachovenmustbeprovided.Itshouldbeascloseaspossibletotheplace
wherethegaslinegoesintotheoven.Itmustbelocatedsuchthatitiseasilyaccessible.Whenstacking
withanotheroven,twoshut-offvalves,oneforeachofthetwoovens,mustbeprovided.
Theoven,wheninstalled,mustbeelectricallygroundedinaccordancewithlocalcodesand/orthe
latesteditionoftheNationalElectricalCodeANSI/NFPANo.70intheUSA(CanadianElectricalCode
CSAStandardC22.1,Part1inCanada).
InEurope,theappliancemustbeconnectedbyanearthencabletoallotherunitsinthecomplete
installationand,thence,toan independentearthconnectionincompliancewithEN60335-1and/or
localcodes.
Theelectricmotor,alltherelatedswitches,interiorlights,andthetimer/buzzerareallconnected
throughthe6-foot(1829mm)powersupplycordlocatedattherearoftheoven.Thesupplycordmust
bepluggedintoaproperlygrounded,three-prongreceptacle.DONOTCUTORREMOVETHE
GROUNDINGPRONGFROMTHEPLUG.
Normalfactoryconnectionsaremadefor120voltsA.C.,60hz,ServiceinUSAandCanadaor240volts
A.C.,50hzserviceinEuropeancommunitycountries.Othervoltagescanbesupplieduponrequest.
Electricalcharacteristicsofthisunitcanbefoundontheratingplatelocatedontherightsideoftheunit.
Thisunitisprovidedwithapermanentlylubricatedelectricmotor.Awiringdiagrammaybefoundonthe
backoftheservicepanelontheright-handsideandinthismanual.
Iftheovenisnotventeddirectlyandisinstalledunderaventilationhood,theunitisreadytobeinstalled
asis.Localinspectorsandventilationspecialistsshouldbeconsultedsothatthedesignandthe
installationofthehoodconformtolocal/municipalcodes.IntheU.K.,followventilationrequirements as
detailedinB.S.5440.
NOTE:
AftertheGasSupplyhasbeenconnected,itisextremelyimportanttocheckallthepipingfor
leaks.Useasoapandwatersolutionoraproductexpresslymadeforthispurpose.Donotuse
matches,candlesoraflameandsoforthtocheckleakssincethesemethodsareextremely
dangerous.
Noexternalregulatorisrequired.
F.ELECTRICALCONNECTION:
G.FLUECONNECTIONVENTILATION:
Installationunderventilationhood(standard):
5