Product Manual

PowerTop V3 Manual www.baintech.com.au
If you require faster charging we recommend using a 20A (maximum) charger suited for Gel batteries with the following
voltage set points:
Bulk 14.2V
Float 13.7V
The external charger is to be connected to the Grey Anderson connector labeled 50A Battery Output.
CHARGING

7
Internal AC charger
ThePowerTopcomeswithaninternal6.6AACcharger.
ThechargeroperateswhentheACplugisconnectedintothe
unit.
WhenchargingwiththeinbuiltACcharger:
1)DisconnectPowerTopunitfromallloadsandturnOFFunit
2)ConnecttheACplugfrom240VACsourcetotheunit.
3)TurnONthePowerTopUnit-MainsLEDwillturnON-Leave
chargingunlfull.
FAST CHARGING

Ifyourequirefasterchargingwerecommendusinga20A(Maximum25A)chargersuitedforAGMbaerieswiththefollowing
voltagesetpoints:
BOOST14.2V
FLOAT13.7V