Product Manual
11.Series and parallel connection of batteries
Advantage of pulse stage: Use pulse current to revive aged battery.
Advantage of recond stage: Allow full charge of battery.
Advantage of Float and Maintain stage: After LED turns green, maintenance charge is
provided so the battery is always in a full state. User will have access to a full battery
whenever it is disconnected from the charger.
6.2 “8” stage charging (Selection switch to “8” stage)
7. Function description
7.1 Remote Control
The charger can be turned ON/OFF by using the “Remote Control” function..
Between
RC+(pin10)
& RC-(pin9)
SW Open
SW Short
Charger
ON
OFF
7.2 2 or 8 stage Charging mode Select
The charger features user selectable 2 or 8 stage charging. The charging prole is
selected by moving the slide switch on the back panel.
Switch
Turn right
Turn left
Charging mode
2 stage charging
8 stage charging
7.3 Charger OK Relay(RY15)
Charger
Normal work
Failure or the
protection function
is activating
Between pin5 and pin6
ON (Short)
OFF(Open)
7.4 Output OK Relay(RY13)
Bank
Battery Full
Charging
Between pin1 and pin2
ON (Short)
OFF(Open)
7.4.1. Bank OK (RY13)
Color of LED
Green
Orange
Temperature sensor comes along with the charger can be connected to the unit to
allow temperature compensation of the charging voltage. If the temperature sensor is
not used, the charger still works normally.
7.5 Temperature Compensation
Select suitable wire gauge based on rated charging current. Refer to the following
table for minimum wire gauge. We highly recommend using RED wire for + connection
and BLACK wire for - connection:
8.Wiring for battery
AWG
14
12
10
7
6
4
CROSS SECTION(mm
2
)
2.1
3.3
5.3
10
16
25
Max.Current(A)
UL1015(600V 105
o
C)
12
22
35
46
60
80
9.Suggested battery capacity
NOTE: 1. Using battery capacity larger than the suggested value will not lead to
damage of battery. The only drawback is it may take longer to fully charge
the battery.
2. If you’re unsure about max allowable charging current of the battery, please
refer to the battery’s technical specication or consult its manufacturer.
10.Suggested No. of cells
Model
PB-600-12
PB-600-24
Battery capacity
135-400AH
70-210AH
PB-600-24 70-210AH
Model
PB-600-12
PB-600-24
Battery capacity
100AH
80AH
PB-600-24 46AH
Number
1~4
1~3
1~2
1. Batteries in series
Voltage can be doubled when 2 batteries
are connected in series. However, the
capacity (AH) will remain the same.
For example, 2 x 12V 100AH batteries
connected in series = 24V 100AH.
2. Batteries in parallel
When 2 batteries are connected in
parallel, voltage remains the same and
the capacity (AH)doubles. For example,
2 x 12V 100AH batteries connected in
parallel = 12V 200AH.
12.Failure correction notes
If you are not able to clear the failure condition, please contact Mean Well or
any of our distributors for repair service.
WARNING: This is a class A product. In a domestic environment this product may
cause radio interference in which case the user may be required to take
adequate measures.
Against recharging non-rechargeable batteries.
Status
Possible Reasons
Ways to Eliminate
Unable to
charge the
battery
LED indicator
does not turn
Green after a
long charging
period
ON/OFF switch in the OFF
position
Switch to the ON position
Battery reverse polarity
Reconnect using correct
polarity
Battery with higher voltage is
connected
Make sure input source is
between 90~264VAC
Battery exceed lifespan or
damaged
Replace with a new battery
Output cables are too thin
Replace with suitable wire
gauge
Use battery with the correct
voltage
Input AC voltage is too low
Bainbridge Technologies warrants this product for a period of 24 months from the
date of purchase.
Bainbridge Technologies will repair or replace any defective product when directly
returned, postage paid, to us with a new or refurbished product.
This decision will be at Bainbridge Technologies discretion.
This warranty will be considered void if the product has suffered any obvious physical
damage or alteration either internally or externally. Bainbridge Technologies does not
cover damage arising from improper use, such as plugging the unit into unsuitable
power sources, or attempts to operate products with excessive power consumption
requirements, or use in unsuitable environments.
A minimum standard service fee of $35.00 plus G.S.T. will apply on all products. If the
product is deemed to be a warranty then this fee will be waived, and the product will
be replaced and/or repaired at no charge.
If there is no fault found with the product the service fee will apply, plus return freight
charges prior to the product being released.
If the product is out of warranty the service fee will be absorbed in the quote for repair.
If the quote for repair is denied then the service fee will apply plus freight before the
goods are released.
NOTE: This warranty is non transferable
NOTE: Reverse polarity & severe voltage surges are not covered by warranty.
Warranty:
The temperature sensor
can either be attached to
the battery or placed in its
surrounding environment
PO Box 7222
Hemmant QLD 4174
Phone: 1300 BAINTECH
Email: info@baintech.com.au
Website: www.baintech.com.au