Operating instructions

65
All temperature setting LEDs are ashing
Temperature sensor defective, refrigerator
works on mid temperature setting.
LED +All temperature setting LEDs are ashing
230V- Heating element defective.
LED + all temperature setting LEDs are
ashing
12V- Heating element defective.
Troubleshooting
Before notifying the authorised Service
Centre, please check whether:
The instructions in the section “Operating
the refrigerator” have been followed.
The refrigerator is level.
It is possible to operate the refrigerator with any
available power source.
Failure: The refrigerator does not cool
sufciently.
Possible cause
Action you can take
q) Inadequate ventilation to the unit.
a) Check that the ventilation grilles are not covered.
q) Thermostat setting is too low.
a) Set Thermostat to a higher level.
q) The condenser is heavily frosted.
a) Check that the refrigerator door closes properly.
q) Too much warm food has been stored
a) Allow warm food to cool down before storage.
q) The appliance has been running for only inside
within short period of time.
a) Check whether the cooling compartment works
after 4 – 5 hours.
q) Ambient temperatures too high.
a) Regularly remove ventilation grilles.
Failure: The refrigerator does not cool in gas
operation mode.
Possible cause
Action you can take
q) Gas cylinder empty.
a) Change gas cylinder.
q) Is the supply shut-off device open?
a) Open the shut-off device.
q) Air in the gas pipe?
a) Switch off the appliance and start again. Repeat
this procedure 3-4 times, if necessary.
Failure: The refrigerator does not cool in 12V
operation.
Possible cause
Action you can take
q) On-board fuse defective.
a) Fit new fuse.
q) On-board battery discharged.
a) Check battery, charge it.
q) Engine not running.
a) Start engine.
q) Heating element defective (please also refer to
failure indication).
a) Please inform the Dometic Customer Services.
Failure: The refrigerator does not cool in 230V
operation.
Possible cause
Action you can take
q)On-board fuse defective.
a) Fit new fuse.
q) No connection to supply voltage.
a) Establish power connection.
q) AES: gas operation despite connection to the
supply voltage.
a) Appliance switches to gas operation due to
insufcient supply voltage (automatically switches
back to 230V operation).
q) Heating element defective (please also refer to
failure indication)
a) Please inform Dometic Customer Services.
Maintenance
Please visit www.dometicapproved.co.uk or
telephone 0844 6260130 to locate your local service
centre. installation may only be carried out by
authorised personnel. We recommend contacting
your Dometic Service Centre.
EN 1949 stipulates that the appliance’s gas
equipment and its associated fume system must be
inspected after installation and a certicate issued.
When using the fridge for extended periods on gas
operation Dometic recommend a seasonal service
is carried out by authorised personnel.
It is the user’s responsibility to arrange for
inspections after purchase.
It is recommended that the gas burner be inspected
and cleaned as necessary at least once a year.
We recommend maintenance following an extended
shutdown of the vehicle.
i