Operating instructions
76
remains on. The device remains in the malfunction
status. Other devices connected to the control panel
can be operated.
Troubleshooting instructions (Combi Gas heater)
Error
Code
Cause Remedy
#17 Summer mode with empty water container switch off device and allow to cool. Fill boiler with water.
warm air outlet blocked Check each of the outlet openings
circulate air intake blocked Remove the blockage from the circulated air intake
#18 Gas pressure regulator frozen Use the regulator heating
Too much Butane in the gas cylinder Use Propane (Butane is unsuitable for heating especially
at temperatures below 10C.)
#21 Room temperature sensor or cable faulty Please contact Truma Customer Services
#24 Potential under-voltage battery voltage too
low <10.4V
Charge the Leisure Battery
#29 Heating element for frostControl has a short
circuit
Disconnect the heating element plug on the electronic
control unit. Replace heating element.
#41 Electronics are blocked Please contact Truma Customer Services.
#43 Over-voltage . 16.4V Check the battery voltage and voltage sources e.g.
charger.
#44 Under-voltage battery voltage too low Charge Battery. Replace any old batteries.
#45 No230V operating Voltage Reconnect the operating voltage 230V.
Faulty 230V Fuse Replace 230V fuse.
Overheating protection has triggered Reset the overheating protection. Allow the heating to
cool down, remove the connection cover and press the
reset button.
#112 Gas cylinder or quick acting valve in the gas
line is closed
Check the gas supply and open the valves.
#212 Combustion air intake or exhaust outlet is
closed
Check the openings for soiling (snow, leaves, ice etc) and
remove.
#255 No panel connedtion between the heater and
the control panel
Please contact Truma Customer Services.
Control Panel cable faulty Please contact Truma Customer Services.