Operating instructions
63
Electrical Operating Instructions (230v)
Ensure that the water heater is full then switch the isolation
switch on. (Usually mounted on the bunk face adjacent to the
gas control switch.)
The water temperature cannot be selected;
temperature is automatically limited to 70°C.
For a faster heating up the appliance can be
simultaneously operated with gas and electrical
power.
General Safety Notes
In the event of leaks in the gas systems or if
there is a smell of gas:
Extinguish all naked ames.
Do not smoke.
Switch off appliance and gas cylinder.
Open the windows
Do not operate any electrical switches
Have the entire system checked by an expert.
Repair Jobs are only to be carried out by an expert.
The Following would invalidate the guarantee:
• Any alteration to the appliance (including cowl.)
• The use of non-Alde spare parts/accessories
• Non observance of the operating instructions
The operating pressure for the gas supply is 30mbar
(or for 28mbar butane/ 37 mbar propane) and must
correspond to the operating pressure of the appliance
(see name plate.)
Do not operate the water heater when refuelling the
vehicle and when in the fuel station.
During initial operation of a brand new appliance (or
after it has not been used for some time), a certain
amount of fumes and a slight smell may be noticed for a
short time. Remedial action here is to immediately run
the heater at maximum output and to ensure adequate
room ventilation.
If the burner makes an unusual noise or if the ame
lifts off, it is likely that the regulator is faulty and it is
essential to have it checked.
i