Operating instructions
38
14C Truma Ultraow Operating
Instructions
Raise the lid, clean both the water socket and the plug of
the pump assembly.
Plug the pump connector into the socket.
Place the pump into the water container, ensuring that
it is fully submerged before operating the system. The
dust cover (8) is to stop contaminates falling into the
water container.
To remove the pump assembly from the Ultraow
Compact Housing, pull the trigger and pull out the hose
plug.
! Do not remove by pulling the hose or electrical cable.
Routine Maintenance
Ensure that the O-ring seal in the hose plug and the
socket are free from dirt.
To aid tting of the plug assembly smear the O-ring with
vegetable oil.
Notes
Never allow the pump to run dry. Always ensure that the
pump is submerged in the water or the life of the pump
will be reduced.
Before winter storage the water system must be
completely drained.
Clean the water system at the start and end of the
season with sterilising uid (see notes under sterilising).
If the pump fails to deliver water; the most likely cause
will be air in the system. Switch off the pump and shake
the pump assembly in the water. Then switch on the
pump again.
Sterilising
When cleaning the water system at the start or end of
the season it is advisable to use non-chlorine based
sterilising uid.
Flush the system thoroughly to remove the effective
uid traces.