Environmental Specifications
Operating Temperature Range
-40°F to 159°F / -40°C to 55°C (solar radiation included)
Rectifier:
When solar radiation:-40ºC to +50ºC
No solar radiation: -40ºC to +55ºC
Discharge: -40°C to 55°C
Battery:
When solar radiation:-40ºC to +45ºC
No solar radiation: -40ºC to +55ºC
Storage Temperature Range
-4°F to 158°F
-20°C to 70°C
Operating Humidity Range
5% to 95% RH, no dewdrops
Altitude
0-4000m (2000m to 4000m). With every 200m altitude increase,
max operating temperature decreases 1°C.
Global Part Numbers
SmartUPS:
EPB41211
200W, 5A/H battery, (1) 48VDC outlet, 4-port exchange, PoE+ Outdoor
SmartUPS. Extended battery support. With network management.
EPB42121
400W, 10A/H battery, (2) 48VDC outlet, Optical, 4-port exchange, (1)
PoE+ Outdoor SmartUPS. Extended battery support. With network
management.
EPB42125
400W, 10A/H battery, (2) 48VDC outlet, Optical, 3-port exchange, (3)
PoE++ Outdoor SmartUPS. Extended battery support. With network
management.
EPB93531
1500W, 20A/H battery, (3) 48VDC outlet, Optical, 3-port exchange, (1)
PoE+ Outdoor SmartUPS. Extended battery
Single power output up to 2 kilowatts maximum,
Support N+1 (N ≤2) power
supply parallel Support battery N+1 (N ≤ 2) parallel, With network