Baicells EG2030C-M2 User Manual V100R001C00 02 All rights reserved © Baicells Technologies Co., Ltd.
About This Document This document introduces the specifications of Baicells EG2030C-M2 CPE and guides users to install and configure it. Copyright Notice Baicells copyrights this specification. No part of this specification may be reproduced in any form or means, without the prior written consent of Baicells. Disclaimer This specification is preliminary and is subject to change at any time without notice. Baicells assumes no responsibility for any errors contained herein.
Contents 1. 2. 3. Product Overview ......................................................................................................... 1 1.1 Introduction .............................................................................................................. 1 1.2 Features ..................................................................................................................... 1 1.3 Appearance ..................................................................................
Figures Figure 1-1 EG2030C-M2 Appearance.......................................................................... 2 Figure 1-3 LED Indicators of EG2030C-M2 ................................................................. 2 Figure 4-1 Login Page .................................................................................................. 8 Figure 4-2 View Status ................................................................................................. 9 Figure 4-3 Set Connection Method ........
Tables Table 1-1 Description of EG2030C-M2 Interface and Button....................................... 2 Table 1-2 LED Indicator Description ............................................................................. 3 Table 2-1 Basic Specification ....................................................................................... 4 Table 2-2 RF Specification ........................................................................................... 4 Table 2-3 SW Specification .......................
1. Product Overview 1.1 Introduction Baicells is a high-tech company dedicated in wireless broadband access solutions and service operation. With the advent of the Internet+ era, the development of WBB is imminent. Through continuous innovation, Baicells launches the world first mobile broadband system based on the Internet architecture and unlicensed spectrum. Baicells can provide series CPEs, include indoor and outdoor unit on different spectrums. Baicells EG2030C-M2 is high performance outdoor CPE.
Figure 1-1 EG2030C-M2 Appearance The EG2030C-M2 interface and button description is given in Table 1-1. Table 1-1 Description of EG2030C-M2 Interface and Button Interface & Button Description Power Switch Power On/Off SIM Support 1.8V/3.0V USIM 2FF RESET Long press over 10 seconds to restore the factory settings LAN 1 RJ45, LAN, 10/100/1000 auto-sensing, auto-MDX The LED indicators are shown in Figure 1-2.
Table 1-2 LED Indicator Description Identity Power WLAN LTE LTE Signal Description Network state Indicator SIM card status indicator Power Indicator 3 LTEs, Indicate connection state and signal strength Color Status Description OFF No Power Supply. Steady On Power on. Steady On WLAN is on. Blanking WLAN is off. OFF LTE disconnected. Steady On LTE connected. All OFF Signal is too weak to attach.
2. Technical Specifications 2.1 Basic Specification Table 2-1 Basic Specification Item Description LTE Standard 3GPP Release 9 Ethernet LAN Port One RJ-45 port 10/100 auto-sensing, auto-MDX LED Indicators Power/LET Signal/WLAN USIM Support 1.8V/3V 2FF Restore Button Tact Button Long press over 10s to restore the factory settings Power Supply Input: Universal range 100V~240V AC Output: 5VDC, 2A Dimension About Weight About 400g Color Pantone white C 2.
2.
2.5 Environment Specification Table 2-5 Environment Specification Item Operating Temperature Storage Temperature Operating Humidity 2.6 Description -10℃ ~ 40℃ -20℃ ~ 70℃ 5% ~ 95% Regulatory Compliance FCC Compliance This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause in terference, and (2) This device must accept any interference, including interference t hat may cause undesired operation of the device. Le présent appareil est conforme aux CNR d' Innovation, Science et Développement économique Canada applicables aux appareils radio exempts de licence.
3. Configuration Guide 3.1 Log in The EG2030C-M2 manages, configures, and maintains the device by web management page. The steps to log in are as follows: 1. In the address column of browser, type in http://192.168.150.1, then press “Enter”, login in page is shown in Figure 3-1. Figure 3-1 Login Page 2. Enter the user name and password, click "LOGIN". After password authentication, you can log on to the web management page. The default user name and password is admin.
Figure 3-2 View Status 3.3 Basic Configuration 3.3.1 LTE Setting To set the LTE Network, perform the following steps: 1. Choose LTE. 2. In the LTE Setting area, configure the LTE network. 3.3.2 Set Connection Method To set the LTE network connection method, perform the following steps: 1. Choose “LTE>connection Method”, enter the setting connection method page, as shown in Figure 3-3.
2. In the connection Method area, set the connection method 3. There are two methods to connect the LTE network, it is needed to choose a method between Auto and Manual, if you want to auto connect to the LET network you should choose the Auto, otherwise you should choose Manual. 4. Click “SAVE & APPLY”. 3.3.3 Set Scan Mode To set the LTE network scan mode, perform the following steps: 1. Choose “LTE>Scan Method”, enter the setting scan method page, as shown in Figure 3-4. Figure 3-4 Set Scan Mode 2.
Figure 3-5 Lock Frequency 4. Click “SAVE & APPLY”. 3.3.5 Lock PCI To lock the PCI, perform the following steps: 1. Choose “LTE>Scan Method”. 2. In the LTE Scan Method area, click PCI Lock to lock the PCI. 3. Click ADD LIST you can choose a band, frequency and PCI, then click Add to add the frequency and PCI to the list, as shown in Figure 3-6.
Figure 3-6 Lock Frequency 4. Click “SAVE & APPLY”.
Appendix A FAQs The POWER indicator does not turn on. Make sure that the power cable is connected properly and the CPE is powered on. Make sure that the power adapter is compatible with the CPE. Fails to Login to the web management page. Make sure that the CPE is started. Verify that the CPE is correctly connected to the computer through a network cable. If the problem persists, contact authorized local service suppliers. The CPE fails to search for the wireless network.
Appendix B Shipping List The product outward appearance, the color take the material object as, the picture only supply reference.