Configuration Guide
60
Figure 7-11 PDSCH Setting
2. Input PDSCH configuration parameters, which description is shown in Table 7-25.
Table 7-25 PDSCH Parameter Description
Parameter Description
Power Control
Enable or disable the power control function.
ON: Enable
OFF: Disable
Power Control Value
Start
The start value of power control.
Range is from -6 to 6.
Power Control Value
End
The end value of power control.
Range is from -6 to 6.
DIMcsLimit
The limit of uplink MCS.
Range is from 0 to 28.
3. Click “Save” to complete the PDSCH setting.
Configure PUCCH
7.16
1. In the left navigation column, select “NR Setting > PUCCH” to enter the PUCCH
page, as shown in Figure 7-12.
Figure 7-12 PUCCH Setting
2. Input PUCCH configuration parameters, which description is shown in Table 7-26.
Table 7-26 PUCCH Parameter Description
Parameter Description
ClpcPucchEnable Enable or disable Clpc PUCCH.