Configuration Guide

55
Parameter Description
ShortDRXCycle Short DRX period.
ShortCycleTimer
The timer of DRX short period. Range is from 0 to 16.
If the value is set to 1, it means 1 * ShortDRXCycle.
If the value is set to 1, 2 * ShortDRXCycle
And so forth.
DRXSlotOffset DRX Slot offset. Range is from 0 to 31.
2. Click Saveto complete the DRX setting.
7.8.6 Voice
1. Click + in the front of Voice to display the voice configuration parameters, as
shown in Table 7-20.
Table 7-20 Voice Parameter Description
Parameter Description
VONR
Voice Over NR.
ON: Enabled
OFF: Disabled
EPS Fallback Type
EPS fallback type, including five types.
EPS Fallback Blind Red
EPS Fallback Meas Red
EPS Fallback Meas HO
PS Meas Red
PS Meas HO
2. Click Saveto complete the voice setting.
7.8.7 GNB
1. Click + in the front of “GNB” to display the gNB configuration parameters, as
shown in Table 7-21.
Table 7-21 GNB Parameter Description
Parameter Description
GNB ID Length The length of GNB ID. Range is from 22 to 32.
GNB ID GNB ID. Range is from 0 to 4294967295.
GNB Name GNB name. Range is from 0 to 150 bytes.
2. Click Saveto complete the gNB setting.