Configuration Guide
44
Parameter Description
EUTRANEnable
Enable or disable the EUTRAN.
ON: Enable
OFF: Disable
BiNRCellEnable
Enable or disable the BiNR cell.
ON: Enable
OFF: Disable
MRTriggerType
MR trigger type.
Event
Period
AbsoluteThreshold Absolute threshold. Range is from 0 to 127.
RelativeThreshold Relative threshold. Range is from -30 to 30.
AbsEnable
Enable or disable the Abs.
ON: Enable
OFF: Disable
KPIPeriod The period of KPI. Range is from 0 to 3279165.
AutoAdjustEnable
Enable or disable the auto adaptive.
ON: Enable
OFF: Disable
AutoRemoveEnable
Enable or disable the auto remove.
ON: Enable
OFF: Disable
AutoRemovePeriod The period of auto remove. Range is from 0 to 3279165.
AutoRemoveMaxCell
The maximum cells of auto remove. Range is from 0 to
65535.
MaxHOtimes The maximum handover time. Range is from 0 to 3279165.
MaxHOSuccess
The maximum successful handover time. Range is from 0
to 100.
3. Click “Save” to complete the ANR setting.
Configure XN
7.5
1. In the left navigation column, select “NR Setting > XN” to enter the XN
configuration page, as shown in Figure 7-5.