Configuration Guide

41
Figure 7-3 SIB Setting
The gNB supports SIB1 to SIB5.
SIB1
The parameter description of SIB1 is shown in Table 7-6.
Table 7-6 SIB1 Parameter Description
Parameter Description
QRxLevMinSIB1
The minimum received level of SIB1. Range is from
-70 to -22.
Qqualminoffset Cell minimum received signal quality offset. This
parameter represents the cell’s minimum received
signal quality offset. Range is from 1 to 8.
QRxLevMinOffset
Cell minimum received level offset. This parameter
represents the cells minimum received level offset
.
It is used only when the UE resides in the VPLMN
and cell selection is triggered due to periodic
searches for high-priority PLMNS. Range is from 1
to 8.
QQualMinSIB1 -
SIB2
The parameter description of SIB1 is shown in Table 7-7.