Badger® Model 310 BadgerMeter, Inc. Loop Powered Analog Output Transmitter Installation & Operation Manual 872019 Rev.
Mechanical installation The Model 310 may be surface mounted onto a panel, attached to DIN rails using adapter clips or wall mounted using two optional enclosures. Location Although the Model 310 is encapsulated, all wiring connections are made to exposed terminals. The unit should be protected from weather and moisture in accordance with electrical codes and standard trade practices. In any mounting arrangement, the primary concerns are ease of wiring and attachment of the programming cable.
Communications cable wiring Field calibration requires a Data Industrial A310 Programming kit (consisting of a custom cable and software) and a PC running Windows® 9x, ME, NT, 2000 or XP. In order to program the Model 310 it must be connected to LoopPower and the A301 cable must be connected between the Model 310 Comm port connector and an available DB9 COM Location of the port on a computer. DIC Communication Port Note: The Data Industrial A301 Cable will work with all 300 Series products.
Model 310 Specifications Power Requirements: Loop Input Voltage 9-35VDC Input Frequency: 0.4 to 10 KHz Load Resistance Max 750Ω@24VDC Output Response Time Varies with filter Temperature (operating): -29°C to 70°C -20°F to 158°F Temperature (storage): -40°C to 85°C -40°F to 185°F Accuracy ± 0.04% of reading over entire span Linearity 0.1% of full scale Warranty Data Industrial Corporation (“Seller”) of 11 Industrial Drive, Mattapoisett, Massachusetts 02739-0740, U.S.A.