CODES
Read Type/Read Method Codes
Read Type Read Method Description Reading Device
R d
A normal read (reading between the high/lows), and was manually
entered into the reading device
ORION Laptop
Trimble Radix
ReadAll
r d
A normal read (reading between the high/lows), but the high/low
values were viewed rst. The reading was manually entered into the
reading device.
ORION Laptop
Trimble Radix
ReadAll
H d
The meter reading was High. The meter was read manually. ORION Laptop
Trimble Radix
ReadAll
h d
The meter reading was High. The high/low values were viewed rst.
The meter was read manually.
ORION Laptop
Trimble Radix
ReadAll
L d
The meter reading was Low. The meter was read manually. ORION Laptop
Trimble Radix
ReadAll
l d
The meter reading was High. The high/low values were viewed rst.
The meter was read manually.
ORION Laptop
Trimble Radix
ReadAll
N N
The meter was not read (Unread) ORION Laptop
Trimble Radix
ReadAll
R D
A normal read (reading between the (high/lows),The meter was read
successfully by radio (Interrogated).
ORION Laptop
Trimble Radix
ReadAll
r D
A normal read (reading between the high/lows), The high/low values
were viewed rst. The meter was read by radio (Interrogated).
ORION Laptop
Trimble Radix
ReadAll
H D
The meter reading was High. The meter was read by radio
(Interrogated).
ORION Laptop
Trimble Radix
ReadAll
h D
The meter reading was High. The high/low values were viewed rst.
The meter was read by radio (Interrogated).
ORION Laptop
Trimble Radix
ReadAll
L D
The meter reading was Low. The meter was read by radio
(Interrogated).
ORION Laptop
Trimble Radix
ReadAll
I D
The meter reading was Low. The high/low values were viewed rst
The meter was read by radio (Interrogated).
ORION Laptop
Trimble Radix
ReadAll
T —
A wire from the ORION endpoint going to the register (water) or Index
(Gas) has been cut or shorted.
ORION Laptop
Trimble Radix
ReadAll
L —
Potential Leak. The ORION endpoint has noticed continuous water
usage in a 24 hour period and has agged the meter with a Potential
Leak.
ORION Laptop
Trimble Radix
ReadAll
t L
A wire from the ORION endpoint going to the register (water) or Index
(Gas) has been cut or shorted. The ORION endpoint (Water) has also
noticed continuous water usage in a 24 hour period and has also
agged the meter with a Potential Leak.
ORION Laptop
Trimble Radix
ReadAll
User Manual
Page 93 June 2014