Hardware Solutions for Gas Utilities User Manual
ORION® Integral Endpoint for American® RPM Series Rotary Gas Meters
REAR ENDPOINT GASKET ATTACHMENT
The gasket should be attached to the endpoint at the factory. If the gasket is not attached, follow these steps.
1. Place the rear gasket on the back of the endpoint. Place the protruding two tines into the two small holes,
located between the two large holes, on each side of the endpoint.
2. Place the three (3) ¼-20 X 3/8 screws through the endpoint and rear gasket, from the front.
The screws are held in place temporarily by the rear gasket.
PLACE ENDPOINT ON GAS METER
1. Place the gas meter adapter plate onto the three (3) screws. Tighten the screws to about 6 inch-pounds.
Rear Gasket
Tines
Front of Endpoint
Screws
3 Screws
Gas Meter
Adapter Plate
Page 10