Hardware Solutions for Gas Utilities User guide
Programming Chart for Roots Meters with RIOTronics Pulser
These are typical values but always verify your particular meter configuration and index variables.
B3 METER WITH CTR INDEX AND RIOTRONICS PULSER
METER SIZE INDEX TYPE
DRIVE VALUE
Cu. Ft./Rev.
INDEX RES
Cu. Ft.
# OF INDEX
DIALS
PROGRAMMER
DESCRIPTION
SUBCOUNTS
8C CTR 5 100 5 5 CuFt REM (100:5) 1 2
11C CTR 5 100 5 5 CuFt REM (100:5) 1 2
15C CTR 5 100 5 5 CuFt REM (100:5) 1 2
2M CTR 5 100 5 5 CuFt REM (100:5) 1 2
3M CTR 5 100 5 5 CuFt REM (100:5) 1 2
5M CTR 5 100 5 5 CuFt REM (100:5) 1 2
7M CTR 5 100 5 5 CuFt REM (100:5) 1 2
11M CTR 5 100 5 5 CuFt REM (100:5) 1 2
16M CTR 50 100 6 50 CuFt REM (100:6) 10 1
23M CTR 50 100 6 50 CuFt REM (100:6) 10 1
38M CTR 50 100 6 50 CuFt REM (100:6) 10 1
56M CTR 50 100 6 50 CuFt REM (100:6) 10 1
B3 METER WITH TC (Temperature compensated) INDEX AND RIOTRONICS PULSER
8C TC 50 100 5 50 CuFt REM (100:5) 10 1
11C TC 50 100 5 50 CuFt REM (100:5) 10 1
15C TC 50 100 5 50 CuFt REM (100:5) 10 1
2M TC 50 100 5 50 CuFt REM (100:5) 10 1
3M TC 50 100 5 50 CuFt REM (100:5) 10 1
5M TC 50 100 5 50 CuFt REM (100:5) 10 1
7M TC 50 100 5 50 CuFt REM (100:5) 10 1
11M TC 50 100 5 50 CuFt REM (100:5) 10 1
16M TC 500 100 6 500 CuFt REM (100:6)100 0
Programming Guide
Page 23 July 2013