Hardware Solutions for Gas Utilities User guide
Programming Chart for Roots Meters with Dresser AMR Adapter
These are typical values but always verify your particular meter configuration and index variables.
B3 METER WITH CTR INDEX AND AMR ADAPTER
METER SIZE INDEX TYPE
DRIVE VALUE
Cu. Ft./Rev.
INDEX RES
Cu. Ft.
# OF
INDEX
DIALS
PROGRAMMER
DESCRIPTION
SUBCOUNTS
8C CTR 10 100 5 10 CuFt INT (100:5)10 1
11C CTR 10 100 5 10 CuFt INT (100:5)10 1
15C CTR 10 100 5 10 CuFt INT (100:5)10 1
2M CTR 10 100 5 10 CuFt INT (100:5)10 1
3M CTR 10 100 5 10 CuFt INT (100:5)10 1
5M CTR 10 100 5 10 CuFt INT (100:5)10 1
7M CTR 10 100 5 10 CuFt INT (100:5)10 1
11M CTR 10 100 5 10 CuFt INT (100:5)10 1
16M CTR 100 100 6 100 CuFt INT (100:6)100 0
23M CTR 100 100 6 100 CuFt INT (100:6)100 0
38M CTR 100 100 6 100 CuFt INT (100:6)100 0
56M CTR 100 100 6 100 CuFt INT (100:6)100 0
B3 METER WITH TC (Temperature compensated) INDEX AND AMR ADAPTER
8C TC 100 100 5 100 CuFt INT (100:5)100 0
11C TC 100 100 5 100 CuFt INT (100:5)100 0
15C TC 100 100 5 100 CuFt INT (100:5)100 0
2M TC 100 100 5 100 CuFt INT (100:5)100 0
3M TC 100 100 5 100 CuFt INT (100:5)100 0
5M TC 100 100 5 100 CuFt INT (100:5)100 0
7M TC 100 100 5 100 CuFt INT (100:5)100 0
11M TC 100 100 5 100 CuFt INT (100:5)100 0
16M TC 1000 100 6 1000 CuFt INT (100:6)100 0
Programming Guide
Page 21 July 2013