Hardware Solutions for Gas Utilities Owner's manual
RF Quick Read - All Endpoints
The example below is for ORION Migratable or Fixed Network (in mobile mode) endpoints. If you are reading ORION Classic
endpoints, perform the same steps using the ORION CE button.
OTE:N To read both ORION Migratable and ORION Classic endpoints simultaneously, see "Changing Quick Read Technology"
on page35.
1. Click Quick Read on the main menu.
2. Click the ORION ME button to start.
Result: The ORION ME button becomes green to indicate communication with the endpoints.
The elds on the screen begin to ll with readings and the Statistics section changes to reect the elapsed time and number
of readings.
Figure 42: ORION ME Quick Read
3. Click the ORION ME button again to pause or stop the Quick Read.
Result: The button becomes clear and the readings stop.
For a single endpoint read:
4. To view readings for a single endpoint serial number, click the row of the endpoint you want to read.
Result: The endpoint serial number lls in the Limit to Single S/N eld.
5. Click the ORION ME button again.
Result: The button becomes green and the readings that are displayed are for the single endpoint serial number
you selected.
6. Click the ORION ME button again to stop the Quick Read.
QUICK READ
Page 34 April 2014ORION® Endpoint Utility