Hardware Solutions for Gas Utilities Owner's manual
Meter Information
Field Label
Displays For
DescriptionEndpoint Technology Encoder Type
Meter Size and
Type
ME, SE ELCD, HRE,
ENC, RTR
The size and type of the meter for which the encoder
was programmed.
Unit of Measure ME, SE ELCD, HRE,
ENC, RTR
The unit of measure as defined by the encoder: cubic meters,
cubic feet, gallons, imperial gallons or liters.
Encoder Type ME, SE ELCD, HRE, ENC The encoder protocol.
Dials ME, SE ELCD, HRE, ENC The encoder dial resolution as reported from the encoder.
Reverse Flow
Total
ME, SE ELCD The total reverse flow units measured by the encoder or the
E-Series meter.
Drive Circle ME, SE, CE Gas Displays after initial read for gas endpoints only. Provides access
to a read-only screen displaying the possible drive circles for the
gas endpoint.
Direction ME, SE Gas The direction for the drive gear.
Pressure Comp ME, SE, CE Gas The gas pressure factor.
Flow Rate Study (ORION ME and SE only)
Field Label
Displays For
DescriptionEndpoint Technology Encoder Type
Start Date Time ME, SE All Date and time the Flow Rate Study was started. Fills when Get
button is selected.
Intervals ME, SE All The number of five-minute Intervals collected during the Flow Rate
Study. Fills when Get button is selected.
Min Max Total ME, SE All The Minimum and Maximum flow, and the Total counts collected.
The fields fill when Get button is selected.
GPS Location (ORION ME and SE only)
Field Label
Displays For
DescriptionEndpoint Technology Encoder Type
Latitude ME, SE All Geographic coordinate specifying north-south position of
the endpoint.
Longitude ME, SE All Geographic coordinate specifying east-west position of
the endpoint.
Advanced Endpoint Functions (ORION ME and SE only)
Field Label
Displays For
DescriptionEndpoint Technology Encoder Type
Battery Status ME, SE All Visual indicator of the endpoint battery status.
IR PROGRAMMING
Page 19 April 2014 ORIONĀ® Endpoint Utility