Hardware Solutions for Gas Utilities Owner's manual

Status Indicators
Box is checked when an alert is reported. The status fields that display depend on the encoder and endpoint type.
Field Label
Displays For
DescriptionEndpoint Technology Encoder Type
Cover Removal ME, SE Gas Endpoint is reporting a potential gas meter index cover tamper.
Encoder Empty Pipe ME, SE ELCD E-Series meter is reporting a no flow condition in the pipe.
Encoder End of Life ME, SE ELCD Encoder or E-Series meter is reporting to the endpoint that the
encoder battery life indicator has been activated.
Encoder Error ME, SE ELCD,
HRE, ENC,
Permalog
Encoder is reporting a device error to the endpoint.
Encoder Programmed ME, SE ELCD Encoder or E-Series meter is reporting to the endpoint that it
has been reprogrammed via IR.
Encoder Removal ME, SE ELCD Encoder is reporting a removal condition to the endpoint.
Encoder Tamper ME, SE ELCD Encoder is reporting a tamper condition.
Encoder Temp ME, SE ELCD Encoder or E-Series meter is reporting to the endpoint that it
senses temperatures outside the specified range.
Endpoint
Programmed
ME, SE All Endpoint was programmed via IR.
Index Changed ME, SE RTR and Gas Endpoint is reporting that the reading (odometer setting)
was changed.
Leak ME, SE, CE HRE, ENC,
RTR, Permalog
Endpoint is reporting a potential leak condition.
ELCD Encoder or E-Series meter is reporting a potential leak condition
to the endpoint.
Low Battery ME, SE All Endpoint is reporting a low battery.
Mobile Mode ME, SE All Endpoint is communicating in mobile mode.
No Usage ME, SE, CE HRE, ENC,
RTR and Gas
Endpoint is reporting a no usage condition.
ELCD Encoder or E-Series meter is reporting a potential no usage
condition to the endpoint.
Reverse Flow ME, SE, CE HRE, ENC
and Gas
Endpoint is reporting a reverse flow condition.
ELCD Encoder or E-Series meter is reporting a reverse flow condition
to the endpoint.
Sensor Error ME, SE ELCD E-Series only. Meter is reporting a sensor error or meter alarm
other than empty pipe or low temp.
Tamper ME, SE, CE ELCD, HRE,
ENC, RTR,
Permalog and
Gas remotes
Endpoint is reporting a tamper. This condition occurs when the
wire between the encoder and the endpoint is cut or shorted, or
the encoder is not connected.
OTE:N For more information about status indicators, refer to the following documents, available at www.badgermeter.com:
HR-E, ENC and RTR: Refer to the ORION Water Endpoint Product Data Sheet for the endpoint type.
HR-E LCD: Refer to the HR-E LCD Encoder Installation and Programming manual.
E-Series: Refer to the E-Series Ultrasonic Meters User Manuals.
IR PROGRAMMING
Page 18 April 2014ORION® Endpoint Utility