Hardware Solutions for Gas Utilities Owner manual
ORION® Gas Endpoints, Integral Endpoint for American® Residential Gas Meters
PLACE THE ENDPOINT AND INDEX ON AN AMERICAN GAS METER
Verify that the rear gasket does not interfere with the endpoint drive shaft. Verify that the gasket fits around the semi-circular
cut out guide.
Rear gasket
Endpoint
drive shaft
Cut out guide
Figure 18: Endpoint and index placement
Placing a Two-Feet Dial
Align the rear endpoint drive pawl and the gas meter pawl. Place the four (4) ¼-20 X 3/8" endpoint screws against the holes in
the gas meter. See Figure 19.
Gas meter pawl
Endpoint pawl
Figure 19: Align endpoint drive pawl and gas meter pawl
Placing a One-Foot Index
Place the endpoint against the gas meter. Place the endpoint drive pawl so it is around the gas meter pawl. See Figure 20.
Gas meter pawl
Endpoint
pawl
Figure 20: Endpoint drive pawl placement around gas meter pawl
Tighten the four (4) endpoint screws (20 inch-pounds max).
Page 12 July 2014