Hardware Solutions for Gas Utilities Manual

Installation Manual
AMERICAN COMMERCIAL DIAPHRAGM AND TURBINE METERS WITH WIRE
SEAL SECURITY SCREW
Index and Index Cover Plate Removal from American Meter with Seal Security Screw
1. Remove the wire security seal from the index cover mounting screw.
Figure 1: Wire security seal
2. Use a large screwdriver to remove the four (4) 18-8 index cover mounting plate screws and American index.
Discard the four screws.
Figure 2: Remove screws on index cover mounting plate
3. Remove the American index and mounting plate.
Figure 3: Remove index mounting plate
Page 7 July 2014