ORION® Gas Endpoints Integral Endpoint for American® Commercial Gas Meters ORI-UM-00907-EN-03 (July 2014) Installation Manual
ORION® Gas Endpoints, Integral Endpoint for American® Commercial Gas Meters Page ii July 2014
Installation Manual CONTENTS Disclaimer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Questions Or Service Assistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Product Identification . . .
ORION® Gas Endpoints, Integral Endpoint for American® Commercial Gas Meters DISCLAIMER The user/purchaser is expected to read and understand the information provided in this manual, follow any listed safety precautions and instructions and keep this manual with the equipment for future reference. Misuse, mishandling and/or inadequate maintenance may impair performance and/or compromise safety.
Installation Manual LICENSE REQUIREMENTS This device complies with Part 15 of FCC Rules. Operation of this device is subject to the following conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
ORION® Gas Endpoints, Integral Endpoint for American® Commercial Gas Meters ORION INTEGRAL ENDPOINT/HARDCASE GAS METER IDENTIFICATION ORION integral endpoints for gas meters are designed for use with American hardcase gas meters: Gas Meter Manufacturer: American® Meter American Gas Meter Models: AL-800, AL-1000, AL-1400, AL-2300, AL-5000 and GTS/GTX Turbine Meters INSTALLATION OF ORION INTEGRAL COMMERCIAL ENDPOINT This manual describes two types of ORION endpoint installations on an American gas meter.
Installation Manual AMERICAN COMMERCIAL DIAPHRAGM AND TURBINE METERS WITH WIRE SEAL SECURITY SCREW Index and Index Cover Plate Removal from American Meter with Seal Security Screw 1. Remove the wire security seal from the index cover mounting screw. Figure 1: Wire security seal 2. Use a large screwdriver to remove the four (4) 18-8 index cover mounting plate screws and American index. Discard the four screws. Figure 2: Remove screws on index cover mounting plate 3.
ORION® Gas Endpoints, Integral Endpoint for American® Commercial Gas Meters Adding Additional Labels If the utility chooses to add an additional label, follow the steps below. If not, see "Install The Orion Integral Endpoint And American Cover Plate" on page 9. Serial number label Figure 4: Serial number label 1. With a needle nose pliers pull the plastic cover plate down and off. See Figure 5. Figure 5: Remove plastic cover 2. Place a new serial number tag above the one on the endpoint.
Installation Manual ORION INTEGRAL ENDPOINT KIT FOR AMERICAN COMMERCIAL DIAPHRAGM AND TURBINE METER WITH WIRE SEAL SECURITY SCREW ORION integral endpoint 2 large tamper plugs 4 screws 2 seal caps 2 washers 2 small tamper plugs Figure 8: ORION integral endpoint kit NNOTE: The screws provided in this installation kit are not drilled for wire seals. Therefore, the wire seal is replaced with plastic seal caps provided in the kit.
ORION® Gas Endpoints, Integral Endpoint for American® Commercial Gas Meters 2. When mounting an ORION integral endpoint to a gas meter make sure the endpoint drive pawl engages the gas meter drive pawl. These two drive pawls must mate without causing any binding or potential for disengagement. Test to ensure the pawls are engaged and moving freely. IIMPORTAN Placing endpoint on meter incorrectly may damage the output seal of the gas meter.
Installation Manual 5. Use four (4) 18-18 X 3-1/2 supplied mounting screws to attach the index, cover plate and ORION integral endpoint to the gas meter. Place two screws, with a washer on each, into two corners of the cover mounting plate. Washer Figure 13: Placement of screws with washer 6. Place two of the screws, without washers, through the white seal caps. Place them in the other two corners of the cover mounting plate. Figure 14: Placement of screw with white seal cap 7.
ORION® Gas Endpoints, Integral Endpoint for American® Commercial Gas Meters PROGRAM THE ORION INTEGRAL ENDPOINT Badger Meter uses a handheld programmer/data collector system to process and display screens. Figure 16: Sample handheld, IR read head and cable Please reference the Programming Guide for ORION gas endpoints and the manual for the handheld system. Programming Procedure To program the endpoint, align the IR port of the handheld optic read head with the endpoint IR port.
Installation Manual COMPLETE THE INSTALLATION After programming, add seal caps to the front and rear screws of the index cover plate. Only the front screw is shown below. Figure 18: Add seal caps on index cover plate If the index mounting seal caps were removed, replace them with the extra caps provided in the installation kit.
ORION® Gas Endpoints, Integral Endpoint for American® Commercial Gas Meters AMERICAN INTEGRAL COMMERCIAL DIAPHRAGM AND TURBINE METERS WITH PLASTIC SECURITY SEALS Index and Index Cover Plate Removal from American Meter with Plastic Security Seals 1. Use a large screwdriver to remove the four (4) 18-8 index cover mounting plate screws and American index. Discard the four screws. Figure 20: Remove index mounting plate screws 2. Remove the American index and mounting plate.
Installation Manual Adding Additional Labels If the utility chooses to add an additional label, follow the steps below. If not, see "Install The Orion Integral Endpoint And American Cover Plate" on page 16. Serial number label Figure 22: Serial number label 1. With a needle nose pliers, pull the plastic cover plate down and off. See Figure 23. Figure 23: Remove plastic cover 2. Place a new serial number tag above the one that is on the endpoint. Figure 24: Place new serial number tag 3.
ORION® Gas Endpoints, Integral Endpoint for American® Commercial Gas Meters ORION INTEGRAL ENDPOINT KIT FOR AMERICAN COMMERCIAL DIAPHRAGM AND TURBINE METER WITH PLASTIC SECURITY SEALS ORION integral endpoint 4 washers 4 screws 6 small tamper plugs Figure 26: Inetgral endpoint kit INSTALL THE ORION INTEGRAL ENDPOINT AND AMERICAN COVER PLATE Use care when handling the ORION integral endpoint to insure the drive pawl is not subjected to any physical abuse.
Installation Manual 2. When mounting an ORION integral endpoint to a gas meter make sure the endpoint drive pawl engages the gas meter drive pawl. These two drive pawls must mate without causing any binding or potential for disengagement. Test to ensure the pawls are engaged and moving freely. IIMPORTAN Placing endpoint on meter incorrectly may damage the output seal of the gas meter Endpoint drive pawl Meter drive pawl Figure 28: Mate drive pawls of endpoint and meter 3.
ORION® Gas Endpoints, Integral Endpoint for American® Commercial Gas Meters 5. Use four (4) 18-18 X 3-1/2 supplied mounting screws and a washer on each to attach the index, cover plate, and ORION integral endpoint to the gas meter. Washer Figure 31: Attach index and cover plate to endpoint 6. Tighten all screws evenly with a large screwdriver to approximately 70 inch-lbs.
Installation Manual Programming Procedure To program the endpoint, align the IR port of the handheld optic read head with the endpoint IR port. Figure 34: Line up the handheld IR port with the endpoint IR port COMPLETE INSTALLATION After programming, add seal caps to the front and rear index cover screws. Only the front screws are shown below. Figure 35: Add seal caps If the index mounting screw seal caps were removed, replace them with the extra caps provided in the installation kit.
Making Water Visible® MAKING WATER VISIBLE and ORION are registered trademarks of Badger Meter, Inc. Other trademarks appearing in this document are the property of their respective entities. Due to continuous research, product improvements and enhancements, Badger Meter reserves the right to change product or system specifications without notice, except to the extent an outstanding contractual obligation exists. © 2014 Badger Meter, Inc. All rights reserved. www.badgermeter.