Hardware Solutions for Gas Utilities Manual
Special Reports
Special Reports for the ORS application are described below. Each report is automatically updated as the meter reader views
the report and ORS gathers data.
Summary Report
The Summary report of the current status of in-progress meter readings is displayed in the lower half of the screen as shown
in Figure 56.
Figure 56: Summary report
Total Accounts The number of accounts loaded in the route file.
Total Services The total number of services included in those accounts.
Time Spent Reading The total amount of time (in minutes) ORS was in active reading mode.
Time Spent Paused The total amount of time ORS was paused.
Service Read The number of services/endpoints that were read.
Unread Services The number of services/endpoints that were not read.
Out-of-Route Services The number of out of route services that were read.
Low Read Exceptionally low meter readings.
High Read Exceptionally high meter readings.
Tamper The number of ORION endpoints reporting a tamper condition.
Encoder Error The number of ORION endpoints connected to encoders reporting an error condition.
Potential Leak The number of ORION water endpoints reporting a potential leak condition.
Reverse Flow The number of endpoints connected to encoders which have reported a reverse
flow condition.
No Usage The number of ORION endpoints reporting no usage.
REPORTS
Page 54 April 2014ORIONĀ® Meter Reading System (ORS)