ORION® Gas Endpoints Integral Endpoint for Roots® B3 Series Rotary Gas Meters IMPORTANT: This manual contains important information. READ AND KEEP FOR REFERENCE. ORI-I-68 (4-11) 62014-104 Rev.
ORION® Integral Endpoint for Roots® B3 Series Rotary Gas Meters Page ii (4-11)
Installation Data Contents DISCLAIMER.......................................................................................................................................5 QUESTIONS OR SERVICE ASSISTANCE.............................................................................................5 PRODUCT IDENTIFICATION...............................................................................................................5 SCOPE OF MANUAL.............................................................
ORION® Integral Endpoint for Roots® B3 Series Rotary Gas Meters Page iv (4-11)
Installation Data DISCLAIMER The user/purchaser is expected to read and understand the information provided in this manual, follow any listed safety precautions and instructions and keep this manual with the equipment for future reference. Misuse, mishandling and/or inadequate maintenance may impair performance and/or compromise safety. QUESTIONS OR SERVICE ASSISTANCE If you have questions regarding the product or this document contact: Badger Meter, Inc. P.O.
ORION® Integral Endpoint for Roots® B3 Series Rotary Gas Meters PRODUCT UNPACKING AND INSPECTION NOTE: If damage to the shipping container is evident upon receipt, request the carrier to be present when the product is unpacked. Carefully open the shipping package, follow any instructions that may be marked on the exterior. Remove all cushioning material surrounding the product and carefully lift the product from the package.
Installation Data INSTALLATION TOOLS AND MATERIALS Pliers Phillips screwdriver If battery powered driver is used, ensure torque maximums are not exceeded (usually 15 inch-pounds). Badger Meter handheld programmer/data collector All ORION units are shipped from the factory unprogrammed. Using the handheld programmer, the installer must program ORION to a specific endpoint.
ORION® Integral Endpoint for Roots® B3 Series Rotary Gas Meters ORION INTEGRAL ENDPOINT ON A DRESSER/ROOTS B3 ROTARY GAS METER EQUIPPED WITH THE DRESSER/ROOTS AMR ADAPTER Roots Rotary Gas Meter ORION Integral Endpoint ORION integral endpoints easily and quickly install on Roots gas meters. When installed on rotary meters, the ORION integral endpoint does not use a local index assembly.
Installation Data ORION INSTALLATION KIT FOR A ROOTS B3 ROTARY GAS METER Spacer Rear Gasket Endpoint 4 Screws 10 x 24 x ½ Front Gasket 4 Screws 8 x 16 x ½ Cover 4 Tamper Plugs IMPORTANT! Installation of the integral endpoint onto a Roots meter requires the use of an AMR adapter plate which is available from Dresser/Roots. Use the Roots rotary meter installation instructions for dismantling the top portion of the meter.
ORION® Integral Endpoint for Roots® B3 Series Rotary Gas Meters SPACER ON GAS METER 1. Place the spacer, included in kit, onto the gas meter drive shaft. Plastic Drive Pawl Spacer on Drive Shaft 2. Place the drive pawl over the spacer and onto the drive shaft. Drive Pawl on Drive Shaft Drive Pawl onto Drive Shaft ATTACH REAR ENDPOINT GASKET The gasket should be attached to the endpoint at the factory. If the gasket is not attached, place the rear gasket on the rear of the endpoint.
Installation Data ATTACH ENDPOINT TO ADAPTER PLATE OF GAS METER 1. Place the endpoint over the gas meter adapter plate. Endpoint Gas Meter Adapter Plate 2. Adjust the endpoint drive shaft on the gas meter drive pawl. Gas Meter Drive Pawl Endpoint Drive Shaft 3. Screw the endpoint down with four (4) 10 x 24 screws. Tighten the screws to about 6 inch-pounds.
ORION® Integral Endpoint for Roots® B3 Series Rotary Gas Meters PLACE THE FRONT GASKET ON THE ENDPOINT Place the gasket so that its two holes go over the two locating tines. Be sure the notched end goes around the guide pin at the side of the endpoint. Two Holes Over Tines Notched End Around Guide Pin Be certain that the stepped edge is toward the endpoint boot and seated between the endpoint sealing face and the alignment tabs. The weep holes in the gasket should be facing downward.
Installation Data PROGRAM THE ENDPOINT Badger Meter uses a handheld programmer/data collector system to process and display screens. Trimble Ranger and IR Read Head and Cable Please reference the Programming Guide for ORION gas endpoints and the manual for the handheld system, ORI-IOM-52 Trimble Ranger Installation and Operation Manual. Programming Procedure To program the endpoint, align the IR port of the handheld optic read head with the endpoint IR port.
ORION® Integral Endpoint for Roots® B3 Series Rotary Gas Meters INSERT TAMPER PLUGS For security purposes, insert the four (4) red tamper plugs (supplied) in the screw holes and push them in. Tamper Plugs INSTALLATION COMPLETE The ORION integral endpoint is now installed on the Roots residential rotary gas meter.
Installation Data This page intentionally blank.
ORION is a registered trademark of Badger Meter, Inc. Other trademarks appearing in this document are the property of their respective entities. Copyright 2011, Badger Meter, Inc. All rights reserved. Due to continuous research, product improvements and enhancements, Badger Meter reserves the right to change product or system specifications without notice, except to the extent an outstanding contractual obligation exists. Badger Meter | P.O.