Hardware Solutions for Gas Utilities Instruction Manual

ORION® Fixed Network (SE) II Network Gateway Transceiver
BATTERY BACKUP REPLACEMENT
If a battery replacement is required, complete the installation steps as detailed below in the order presented.
OTE:N It is not necessary to disconnect AC power from the gateway before removing the cover and replacing the battery.
Tools and Materials
Rechargeable battery pack kit with enclosure cover (67018-001)
#2 slotted or Phillips screwdriver (customer-supplied)
MPORTANTI
Working with electronics requires the use of proper electrostatic discharge (ESD) protection. Grounded wrist straps are
recommended when working inside the enclosure.
1. Using a #2 slotted or Phillips screwdriver, remove the enclosure cover by unscrewing four corner-cover screws
(Figure 42). The cover will not be used again and can be discarded.
Remove Four Corner Screws
Cover Removed
Figure 42: Enclosure cover removal
2. Squeeze the connector latch (Figure 43) of the battery connector on the circuit board and carefully pull on the
connector to remove it from the circuit board pin contacts. Do NOT pull on the connector wires. If the connector is
stuck, it can need to be gently rocked back and forth while pulling.
Figure 43: Battery connector
OTE:N The battery is held in place by the enclosure cover only. No other adhesive or locking mechanism is used.
Battery Connector
Latch
Page 32 March 2014