Hardware Solutions for Gas Utilities Instruction Manual

Installation Manual
7. Place a lock washer and nut on each bolt and tighten the nuts 100…150 inch-pounds to ensure the gateway is
suciently secured to the pole.
8. Repeat Steps 7 and 8 for attaching the V-block clamp mounting hardware to the bottom bolts of the
mounting backplate.
Side View Back View
Side View
Figure 12: Completed gateway mounting
Banding Mounting
Banding mounting equipment is sized to mount the gateway on a 2-1/2…24-inch outer diameter pole.
MPORTANTI
When using the banding mounting kit for the gateway, use BAND-IT Idex installation practices. Refer to
www.band-it-idex.com/en/Literature/Tool_Instructions/P05886.pdf for more information. This is especially applicable when
mounting on a non-tapered vertical pole, as the banding could loosen over time resulting in the unit sliding down the pole.
To mount the gateway on a pole, gather the banding and locking equipment.
Figure 13: Banding and locking equipment
Page 15 March 2014