Hardware Solutions for Gas Utilities Instruction Manual

ORION® Fixed Network (SE) II Network Gateway Transceiver
Using V-block Mounting Clamps
The V-block mounting clamps are sized to mount the gateway on a vertical or horizontal pole with outer diameters ranging
from 1-1/4… 2-1/2 inches. For mounting on poles larger than 2-1/2 inches, see "Banding Mounting" on page 15.
1. Open the bag of mounting equipment.
2. Place two bolts (3/8-16 x 5 inches) through the holes in the top of the gateway mounting backplate (Figure 10). Use
the backplate circular pattern holes for horizontal installation.
3. Place a clamp onto the bolts, as shown below.
4. Place a lock washer and nut onto each bolt, as shown below.
OTE:N The lock washer and nut nearest the enclosure mounting bracket can be omitted when mounting on smaller
diameter poles to provide additional clamping distance.
Figure 10: Attach hardware
5. Tighten the two nuts with a 9/16-inch or adjustable wrench so that each lock washer is fully compressed and at.
6. Repeat Steps 2 through 5, attaching a clamp to the bottom of the gateway mounting backplate. Position the gateway
on the pole and place a clamp on the top bolts.
Figure 11: Transceiver positioning and clamps
Lock Washers
Nuts
Bolts
Clamps
Page 14 March 2014