Remove Old Index
1. Use a screwdriver to puncture and remove the tamper plugs, if present.
2. Use a Phillips screwdriver to remove and discard the four (4) mounting screws and the cover. See Figure 1.
Figure 1: Unscrew mounting screws
3. Remove and discard the index. The straight-face index will be replaced by a slant-face index included in the installation kit.
See Figure 2.
Slant-face
meter index
Straight-face
meter index
Figure 2: Removal of straight-face index, replace with slant-face index
4. Remove and discard the gasket.
Figure 3: Gasket placement
OTE:N Use a putty knife to clean the meter surface of all gasket remnants that might limit the effectiveness of the
new gasket.