4. Install two (2) 8-16 x ½" index mounting screws part way into the front of the endpoint. They will be tightened later.
See Figure 8.
Figure 8: Intallation of index mounting screws
OTE:N Care must be taken when placing the index units on an endpoint. The front drive pawls must mate without causing
any binding or potential for disengagement. See Figure 9.
Drive pawls
Figure 9: Drive pawls
5. Place the gas meter index on the endpoint screws. Tighten screws to 15 inch-pounds maximum. See Figure 10.
Figure 10: Placement of meter index
6. Place the index, endpoint and housing gasket assembly on the adapter. Be sure to align the three posts on the adapter
with the three holes in the assembly. See Figure 11.
Page 10 July 2014