Hardware Solutions for Gas Utilities Owner manual
ORION® Integral Endpoint for Sensus® Residential Gas Meters
3. Use a small screwdriver to remove the index. Discard the two (2) screws.
4. Completely remove and discard the old gasket.
Shown below are Sensus gas meters with the index and gasket removed. Also shown is the gearing for the 2 FT³ and
1 FT³ meters.
Some models of the Sensus residential meter have a cover screw situated in the center of the index box as shown below.
If so, this screw needs to be removed and replaced with the ¼-20 x ¾” machine screw (supplied in the installation kit) which
has a smaller head. This allows the ORION housing to properly interface with the meter body.
2 FT³
Meter
1 FT³
Meter
11-Tooth Gear
24-Tooth Gear
Use a putty knife
to clean the meter
surface of all gasket
remnants that might
limit the
eectiveness of the
new gasket.
Screw to be
Replaced
Page 8
(4-11)