Hardware Solutions for Gas Utilities Owner manual

ORION® Integral Endpoint for Sensus® Residential Gas Meters
Gasket Attachment
The gaskets should be attached to the endpoint at the factory. If the gaskets are not attached:
1. Place the endpoint gasket on the back of the endpoint.
• Place the two slots through the guide pins.
• Place the gasket so the rounded part goes under the endpoint rear drive gear.
2. Place the lens gasket on the other side of the endpoint.
• Place the gasket so that its notched hole goes around the upper left screw hole.
• Place the other gasket holes over the screw holes.
• Be certain that the stepped edge is toward the endpoint boot and seats on the endpoint sealing face.
Gasket Slots
through Guide Pins
Rounded Part of Gasket
under Endpoint Gear
Gasket Notched
Hole
11- or 24-Tooth
Gears
Endpoint Boot
Stepped Edge
Endpoint Sealing
Face
Page 10