WIRING CONNECTION INSTRUCTIONS
There are three types of wiring connections:
1. to a volume corrector
2. to a gas RT with gel caps
3. to an alternative electric or mechanical switch closure
Regardless of the mounting method, the remote endpoint should be mounted so the wire exits the module bottom.
The wire should be secured to the pipeline or other stationary object using cable ties (not supplied) or other means.
The remote ORION remote endpoint is supplied with a six (6) foot long cord, 3-conductor cable.
The wires can be extended to up to 75 feet.
The endpoint wire terminations depend on the corrector device and its proximity to the endpoint.