Manual
MENU
Enters and exits programming mode. Press MENU once to change to programming mode. The mode
indicator on the display will change from RUN to PROGRAM.
Press to scroll through the configuration choices in a bottom-to-top order. For numeric setup, this
button increments numeric values.
Use to scroll through the configuration choices in a top-to-bottom order. For numeric setup, this
button moves the active digit to the right.
ENTER Used to enter menus, to change configurations and to save programming information.
OTE:N If any input value exceeds the meter’s capabilities, the LIMIT indicator will begin to flash indicating an invalid entry.
Press ENTER once to return to the entry screen to reenter the value.
Cover Removal/Reinstallation
It is necessary to remove the MR flow transmitter cover to access the programming keys. Use a Phillips screwdriver to remove
the four screws that hold the cover in place, turning them counterclockwise. When programming is completed, reinstall the
cover. To properly seat the built-in cover gasket, tighten the cover screws clockwise in a crisscross pattern as shown in Figure 8.
Flow Transmitter
3500 PSI/241 BARS MAX
OIL
1
2
3
4
Figure 8: Cover screw tightening sequence
Programming Procedures
The MR flow transmitter has been programmed at the factory according to the specifications that were provided at the time
of order. No further programming is required unless a change has occurred in the original specifications.
If programming is required, the MR flow transmitter allows two basic sets of programming procedures:
1. List Item Selection
2. Numeric Value Entry
List Item Selection Procedure
OTE:N If you are already in PROGRAM mode and the selection to be viewed or changed is already displayed, proceed to step
3 below. If you are in PROGRAM mode and the selection to be viewed or changed is not displayed, press or
and repeat pressing until the desired selection appears. Proceed to step 3.
1. Press MENU. PROGRAM appears in the lower left-hand corner and DISPLAY appears.
2. Press or to move to the desired selection.
3. Press ENTER to view the current selection.
4. If the current selection is desired, press ENTER to confirm. The unit will automatically advance.
5. If current selection must change, press or to scroll through the available choices. Press ENTER to conrm your
selection. The unit will automatically advance.
6. To exit programming, press MENU. The display will change to RUN mode.
User Manual