Ellipse® Pitot Tube Meter BIN Meter PTT-UM-00520-EN-02 (April 2014) User Manual
Ellipse® Pitot Tube Meter, BIN Meter CONTENTS Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Location Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Flow Curves .
User Manual INSTALLATION INSTRUCTIONS 1. The primary station can be installed in any position on vertical or horizontal lines. However for best result, on horizontal liquid lines where the risk of air/gas entrapment in the meter tubing is prevalent, install the element with the head under the horizontal centerline. For horizontal air or gas lines the head should be above the center line to prevent condensation. 2.
Ellipse® Pitot Tube Meter, BIN Meter LOCATION INSTRUCTIONS DISTANCES ARE EXPRESSED IN NUMBER OF NOMINAL PIPE DIAMETERS TWO ELBOWS IN DIFFERENT PLANES THROTTLED VALVE OR REGULATOR 4 27 24 FLOW Preso FLOW RS O METEERS FLUJ FLOW TMET DE DEBI DOR MEDI Regulator or Partially Closed Valve 11 6 4 5 2 Preso FLOW 10 5 2 FLOW TWO ELBOWS IN THE SAME PLANE 11 9 Preso 4 FLOW 6 4 Preso RS O METEERS FLUJ FLOW TMET DE DEBI DOR MEDI 3 Preso RS O METEERS FLUJ FLOW TMET DE DEBI DOR MEDI RS O METE
.2 .3 2 3 4 6 5 10 9 8 7 .3 .4 .5 .6 .7 .8 .9 1 1 .9 .8 .7 .6 .5 .4 ∆P – I N C 20 2 30 3 4 90 80 70 60 50 40 100 .5" 5 6 78 9 1 0 ANNULAR ROUND: BIN O HE S April 2014 F H 2O 3 1" 4 5 6 78 9 1 0 0 1.25" 1.5" USGPM 2 .75" 2" 2 3 2.5" 4 3" 5" 5 6 7 8 91 0 0 0 4" 6" 2 10" 12" 14" 16" 18" 20" 24" 3 4 5 6 78 91 0 0 0 0 2 0 0 0 0 WATER 60° F SCH. 40 PIPE 8" (For other sizes consult factory) NOMINAL PIPE SIZE - SCHED. 40.
– .2 .3 3 4 5 6 7 8 91 0 1 .9 .8 .7 .6 .5 .4 2 3 10 9 8 7 6 5 4 20 2 30 3 4 5 6 7891 0 0 90 80 70 60 50 40 100 ANNULAR ROUND: BIN ES INC H ∆P O 2 Page 6 OF H .5" 1.25" 1.5" 3 4 5 6 7891 0 0 0 1" SCFM 2 .75" NOMINAL PIPE SIZE 2 3" 4" 3 4 5 6 7 8 91 0 0 0 0 2" 2.
.2 1 .3 1 .9 .8 .7 .6 .5 .4 ∆P 2 – I N C 2 4 3 3 4 6 5 5 6 7 8 91 0 10 9 8 7 20 30 90 80 70 60 50 40 100 2 3 4 .5" ANNULAR ROUND: BIN O HE S April 2014 F H 2O 5 6 78 9 1 0 0 .75" 3 4 1.5" SCFM 2 1" 1.25" 2.5" 5 6 78 9 1 0 0 0 2" 3" NOMINAL PIPE SIZE 2 4" 3 4 5" 8" 5 6 7 8 91 0 0 0 0 6" 2 3 4 5 6 78 91 0 0 0 0 0 AIR, 14.
Control. Manage. Optimize. PRESO is a registered trademark of Badger Meter, Inc. Other trademarks appearing in this document are the property of their respective entities. Due to continuous research, product improvements and enhancements, Badger Meter reserves the right to change product or system specifications without notice, except to the extent an outstanding contractual obligation exists. © 2014 Badger Meter, Inc. All rights reserved. www.badgermeter.