Flow Monitor B2800XP Explosion Proof Monitor – Advanced DSY-PM-00279-EN-01 (November 2013) Programming Manual
Flow Monitor, B2800XP Explosion Proof Monitor – Advanced Page ii November 2013
Programming Manual CONTENTS INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 EXPLOSION PROOF ENCLOSURE .
Flow Monitor, B2800XP Explosion Proof Monitor – Advanced ADDITIONAL INPUT OPTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 BATTERY REPLACEMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 MAINTENANCE . . . . . .
Programming Manual INTRODUCTION The B2800XP flow monitor is a state-of-the-art digital signal processing flow monitor designed to provide the user with exceptional flexibility at a very affordable price. Though designed for use with Blancett flow meters, this display can be used with almost any flow meter producing a low amplitude AC output or contact closure signal(s). The B2800XP flow monitor is capable of accepting a low level frequency input for calculating flow rate and total.
Flow Monitor, B2800XP Explosion Proof Monitor – Advanced SPECIFICATIONS Power Supply Options Battery Powered One D size, 1.5V alkaline battery. Loop Powered 4-20 mA loop power. Power Consumption Battery Powered Less than 1 mA @ 1.5V DC. Loop Powered 25 mA (maximum). Alphanumeric Rate and Total Display Eight digit, 0.5 inch high numeric display. Eight character, 0.25 inch high alphanumeric display.
Programming Manual EXPLOSION PROOF ENCLOSURE The EIH Instrument enclosure is designed to house instrumentation and control equipment as well as act as a conduit outlet body in hazardous, abusive and wet locations. The EIH enclosure is approved by Underwriters Laboratories Inc.
Flow Monitor, B2800XP Explosion Proof Monitor – Advanced USE CARE TO PREVENT DIRT, GRIT OR OTHER FOREIGN MATERIAL FROM LODGING ON THREADS. IF SUCH MATERIAL SETTLES ON THREADS, CLEAN WITH KEROSENE OR STODDARD SOLVENT*, THEN RE-LUBRICATE WITH COOPER CROUSE-HINDS TYPE STL THREAD LUBRICANT. 8. Tighten cover set screws to prevent cover from loosening under vibration. * TO AVOID THE POSSIBILITY OF AN EXPLOSION, OXIDATION AND CORROSION, DO NOT USE GASOLINE OR SIMILAR SOLVENT.
Programming Manual INSTALLATION KITS To facilitate installation of the explosion proof B2800XP monitor two sizes of installation kits are available. Hub Size Kit Number Meter Sizes 1/2 in. NPT Hub B280-742 3/8 in., 1/2 in., 3/4 in. with 1/2 in. NPT End Fittings 1 in. NPT Hub B280-737 All Sizes with 1 in.
Flow Monitor, B2800XP Explosion Proof Monitor – Advanced OPERATING THE MONITOR The monitor has two modes of operation referred to as the RUN mode and the PROGRAM mode. Both the RUN mode and the PROGRAM mode display screen enunciators confirm the state of the monitor. A quick glance at the lower left-hand corner of the LCD screen will confirm operating status. Normal operation will be in the RUN mode. To access the PROGRAM mode, press MENU until the first programming screen is displayed.
Programming Manual Select Meter Size At the METER prompt, press UP or RIGHT arrows to select the bore size of your meter. Press ENTER to save meter size choice and advance to the K factor units selection. NNOTE: The meter connection size and the bore size are different. For example, many of the one inch NPT turbines have bore sizes that range from 3⁄8 inch up to one inch Be sure to use the correct bore size or the meter could report incorrect flows and totals.
Flow Monitor, B2800XP Explosion Proof Monitor – Advanced Enter K Factor Unit At the KFAC UNT prompt, press ENTER. The display indicates the current K factor unit. If the current selection is correct, press ENTER to advance to the next parameter. For meters calibrated in gallons, use PUL/GAL; for meters calibrated in cubic meters, use PUL/M3 (pulses per cubic meter); or any other unit choice.
Programming Manual mA DC % 0 MEM MANUAL AutoHOLD FAST MIN MX HOLD MIN MAX LOGGING CANCEL SAVE Hz % ms RANGE SETUP YES REL TB2 Reset 0 NO Pulse Inuput nS mV W ac+dc °F °C V ac+dc + - A mA Pulse Out mV µA V A mA dB dB Freq.
Flow Monitor, B2800XP Explosion Proof Monitor – Advanced Number of Points At the LINEAR prompt, press ENTER. The NUM PTS number will be displayed. Press ENTER to set the number of points you wish to use. Again, the UP arrow increments the value and the RIGHT arrow moves the cursor between digits. When the number of points has been input, press ENTER to move to the first linear segment. Press ENTER and the first linear point’s frequency input will begin to flash FREQ 1.
Programming Manual ADDITIONAL INPUT OPTIONS The B2800XP flow monitor is capable of receiving magnetic pickup input or a contact closure input. Since most Blancett flow meters utilize a magnetic pickup, the monitor is shipped configured for magnetic pickup input. To change to a contact closure input, remove JP2 from the bottom two pins and jumper them to the top two pins. See Figure 5. D 1.5 VOLTS CAUTION DO NOT CONNECT IMPROPERLY CHANGE OR DISPOSE OF IN FIRE. BATTERY MAY EXPLODE OR LEAK. MADE IN U.S.A.
Flow Monitor, B2800XP Explosion Proof Monitor – Advanced BATTERY REPLACEMENT Battery powered monitors use a single 1.5V, D size alkaline battery. When replacement is necessary, use a clean fresh battery to ensure continued trouble-free operation. It is recommended that the total be saved to memory before the battery is removed. DO NOT OPEN EXPLOSION PROOF ENCLOSURE UNLESS THE AREA IS KNOWN TO BE FREE OF HAZARDS.
Programming Manual Pulse Output Signals for Linear Processes Pulse output signals are related to flow rate by a constant, usually referred to as the K factor. The K factor is reported as the number of accumulated pulses that represents a particular volume, such as gallon or liter. K factors are indicated in pulses per unit volume or counts per unit volume. An example of a K factor, normally supplied by the manufacturer, might be 2000 counts per gallon.
x x Note: Only available when either KGS or LBS are Selected See Note Flow Monitor, B2800XP Explosion Proof Monitor – Advanced Figure 6: Advanced programming menu Page 18 November 2013
Programming Manual x x Figure 7: 4-20 mA output programming menu TROUBLESHOOTING GUIDE Trouble No LCD Display Remedy • Battery Powered Version: Check battery voltage. Should be 1.5V DC. Replace if low or bad. • Loop Powered Version: Check for current flow in the loop. Check polarity of the current loop connections for proper orientation. • • • • Check connection from meter pickup to display input terminals. Check turbine meter rotor for debris. Rotor should spin freely.
Flow Monitor, B2800XP Explosion Proof Monitor – Advanced Default K Factor Values Page 20 Meter Size Default K Factor Lower Limit Upper Limit 3⁄8 in. 20,000 16,000 24,000 1/2 in. 13,000 10,400 15,600 3/4 in. 2750 2200 3300 7⁄8 in. 2686 2148 3223 1 in. 870.0 686.0 1044 1-1/2 in. 330.0 264.0 396.0 2 in. 52.0 41.6 62.0 3 in. 57.0 45.6 68.0 4 in. 29.0 23.2 35.0 6 in. 7.0 5.6 8.0 8 in. 3.0 2.4 4.0 10 in. 1.6 1.3 2.
Programming Manual DIMENSIONS 5.25" 5 16 5.10" MENU ENTER 2.60" 4.
Flow Monitor, B2800XP Explosion Proof Monitor – Advanced PART NUMBER INFORMATION B 28 A X X - X X Units of Measure AB - Gallons ED - Barrels HB - Liters ID - Cubic Meters CS - Customer Selectable * Program Level A - Advanced Power Option Mounting Style B - Battery L - Loop X - Explosion proof * NOTE: A dvanced B2800XP monitors only The default is gallons per minute.
Programming Manual INTENTIONAL BLANK PAGE November 2013 Page 23
Blancett is a registered trademark of Badger Meter, Inc. Other trademarks appearing in this document are the property of their respective entities. Due to continuous research, product improvements and enhancements, Badger Meter reserves the right to change product or system specifications without notice, except to the extent an outstanding contractual obligation exists. © 2013 Badger Meter, Inc. All rights reserved. www.badgermeter.