Flow Monitor B2800 Flow Monitor – Advanced DSY-PM-00286-EN-01 (November 2013) Programming Manual
Flow Monitor, B2800 Flow Monitor – Advanced Page ii November 2013
Programming Manual CONTENTS INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 OPERATING THE MONITOR . .
Flow Monitor, B2800 Flow Monitor – Advanced MOUNTING OPTIONS / DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 ADDITIONAL SCALING PARAMETERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Pulse Output Signals for Linear Processes . . . . . . .
Programming Manual INTRODUCTION The B2800 Flow monitor is a state-of-the-art digital signal processing flow monitor, designed to provide the user with exceptional flexibility at a very affordable price. Though designed for use with Blancett flow meters, this display can be used with almost any flow meter producing a low amplitude AC output or contact closure signal. This flow monitor is capable of accepting a low level frequency input for calculating flow rate and total.
Flow Monitor, B2800 Flow Monitor – Advanced SPECIFICATIONS Power Supply Options Battery Powered One D size, 1.5V alkaline battery. Loop Powered Optional 4-20 mA loop power. Power Consumption Battery Powered Less than 1 milliwatt. Loop Powered 25 mA (maximum). Alphanumeric Rate and Total Display Eight digit, 0.75 inch high numeric display. Eight character, 0.38 inch high alphanumeric display. Fixed or toggle modes of operation for flow rate and totalizer display.
Programming Manual OPERATING THE MONITOR The monitor has two modes of operation referred to as the RUN mode and the PROGRAM mode. Both the RUN mode and the PROGRAM mode display screen enunciators confirming the state of the monitor. A quick glance at the lower left-hand corner of the LCD screen will confirm operating status. Normal operation will be in the RUN mode. To access the PROGRAM mode, press MENU until the first programming screen is displayed.
Flow Monitor, B2800 Flow Monitor – Advanced Rate / Total Display And Programming Choices Mode Indicator RUN RELAY1 Programming Keys PROGRAM RELAY2 Units Display And Programming Choices Figure 2: B2800 flow monitor Select Meter Size At the METER prompt, press ENTER. The current meter size number will begin to flash. Using the arrow keys, scroll through the size choices to select the bore size of your meter. Press ENTER to save meter size choice.
Programming Manual Select Units of Measure If a flow amount is desirable, the units for the total must first be chosen. The monitor allows the choice of many common totalization units. (See the SPECIFICATIONS on page 6 for a complete listing of the unit choices.) At the TOTAL UNT prompt, ENTER. The monitor shows the current total units. If the current selection is correct, press ENTER to advance to the next parameter.
Flow Monitor, B2800 Flow Monitor – Advanced Flow 4 mA Setting When the loop powered option is ordered, the flow rate that corresponds to 4 mA must be set. If the current selection is correct, press the RIGHT arrow to advance to the next parameter. If adjustment is required, press ENTER at the FLOW 4MA prompt. The most significant digit will begin to flash. The RIGHT arrow moves the active digit one place to the right for each press of the key.
Programming Manual Linearization Enhanced accuracy can be obtained by linearization of the display. The linearization routine will accept a maximum of ten points. Linearization requires additional calibration data from the meter to be used with the monitor. Typically, calibration information can be obtained in three, five, and ten points from the flow meter’s manufacturer. If linearization is not needed, press the RIGHT arrow key to advance to the next parameter.
Flow Monitor, B2800 Flow Monitor – Advanced Automatic Store Total The monitor is equipped with a store total feature that works automatically, saving the current total to flash memory. The frequency of saves depends on the power supply option chosen. Battery Powered: Once per hour and just before a low battery condition turns the unit off. Loop Powered: Once every ten minutes. BATTERY REPLACEMENT Battery powered monitors use a single 1.5V, “D” size, alkaline battery.
Programming Manual Battery Powered Loop Powered Mag Input 2J Keypad Connector Keypad Connector JP2 1 2 3 4 5 30V DC (Max) 1 10K 2 + Out Pulse 20 mS Pulse Mag Input 2J 3 4 5 6 + mA4-20 + - JP2 1 2 3 4 5 Pulse Inuput 30V DC (Max) TB1 10K Freq. In 20 mS Pulse 1 2 + Out Pulse 3 Pulse Inuput 4 5 6 + mA4-20 + - TB1 Freq. In N/C N/C 10…30V DC 1…5V DC 250 Typ RMAX = (Loop Supply Voltage - 5) 0.
x x Note: Only available when either KGS or LBS are Selected See Note Flow Monitor, B2800 Flow Monitor – Advanced Figure 6: Advanced programming menu Page 14 November 2013
x x Programming Manual Figure 7: 4 - 20 mA programming menu November 2013 Page 15
Flow Monitor, B2800 Flow Monitor – Advanced MOUNTING OPTIONS / DIMENSIONS 5.75" (146.0 mm) RUN RELAY1 4.00" (101.6 mm) PROGRAM RELAY2 7.00" (177.8 mm) 9.25" (235.0 mm) Figure 8: Meter mount 7.00" (177.8 mm) 5.75" (146.0 mm) 4.00" (101.6 mm) 2.40" (61.0 mm) TYP. RUN RELAY1 PROGRAM RELAY2 2.25" 7.00" (57.2 mm) (177.8 mm) TYP. .25" DIA (6.
Programming Manual 5.75" (146.0 mm) RUN RELAY1 4.00" (101.6 mm) PROGRAM RELAY2 7.00" (177.8 mm) 12.25" (311.
Flow Monitor, B2800 Flow Monitor – Advanced ADDITIONAL SCALING PARAMETERS This information is supplied as a general introduction to the basic concepts used to scale rate displays. The applicability of the information is dependent on the type and capabilities of the specific display/monitor used. Flow meters producing an electronic signal are normally supplied in one of two output formats.
Programming Manual gpm Average Frequency **UUT Hz Counts/GAL UUT K (Hz × 60)/NK gpm Error (% FS) 15.00 769.7 3078.59 14.90 –0.65 9.06 466.1 3086.75 9.03 –0.38 5.49 285.2 3118.64 5.52 0.65 3.32 171.7 3103.95 3.32 0.17 2.00 103.6 3101.80 2.01 0.10 **UUT = Unit Under Test If this meter produced an actual linear output, the K factor calculation for the Unit Under Test would be exactly the same for each measurement point.
Flow Monitor, B2800 Flow Monitor – Advanced TROUBLESHOOTING GUIDE Trouble Remedy No LCD Display • Check battery voltage. Should be 1.5V DC. Replace if low or dead. No Rate or Total Displayed • Check connection from meter pickup to display input terminals. • Check turbine meter rotor for debris. Rotor should spin freely. • Check programming of flow monitor. Flow Rate Display Interprets Reading Constantly • • • • This is usually an indication of external noise.
November 2013 A B C D E F G H 12 12 11 11 10 10 9 9 8 8 7 7 6 6 5 5 4 4 3 3 2 D 2 59380 1 B280001 1 A B C D E F G H Programming Manual INSTALLATION DRAWING Page 21 B280001
Flow Monitor, B2800 Flow Monitor – Advanced INTENTIONAL BLANK PAGE Page 22 November 2013
Programming Manual INTENTIONAL BLANK PAGE November 2013 Page 23
Blancett is a registered trademark of Badger Meter, Inc. Other trademarks appearing in this document are the property of their respective entities. Due to continuous research, product improvements and enhancements, Badger Meter reserves the right to change product or system specifications without notice, except to the extent an outstanding contractual obligation exists. © 2013 Badger Meter, Inc. All rights reserved. www.badgermeter.