User Manual

TROUBLESHOOTING GUIDE
Trouble Possible Cause Remedy
No indication on register
Debris in measuring chamber
Broken magnet in magnetic drive
Broken teeth on drive or driven gear
Broken gears or shaft in register assembly
Disassemble meter, clean out debris and
inspect for worn parts
Replace magnetic drive
Replace gear(s)
Replace register
Low flow indication
Flow rate is too low
Bypass valves are leaking
Increase flow above minimum rated gpm
Close valves completely, repair or replace
High flow indication
Gas in liquid
Debris covering a portion of the
meter inlet
Liquid is leaking around the inlet insert
Install gas eliminator ahead of meter
Remove meter from line and clean out debris
Remove meter from line, remove insert and
reset with RTV
REPAIR KIT INFORMATION
Part Number Repair Kit Description
B250-921 Complete Repair Kit; 42 Gallon Barrel; Low Range
B250-925 Complete Repair Kit; 42 Gallon Barrel; Mid Range
B250-923 Complete Repair Kit; 42 Gallon Barrel; High Range
B250-927 Complete Repair Kit; US Gallons
B250-931 Complete Repair Kit; Cubic Meters
B250-922 Repair Kit less Register; 42 Gallon Barrel; Low Range
B250-926 Repair Kit less Register; 42 Gallon Barrels; Mid Range
B250-924 Repair Kit less Register; 42 Gallon Barrels; High Range
B250-932 Repair Kit less Register; US Gallons
B250-928 Repair Kit less Register; Cubic Meters
900 Series Positive Displacement Water Flood Meters
Page 8 September 2013