ELECTRICAL CONNECTIONS
The Magnetoflow
®
7500P electronic converter is enclosed in
a water tight (NEMA 4) aluminum enclosure. A pair of 1/2"
NPT water-tight cord grips is provided for the electrical con-
nections.
Do not remove these cord grips unless you replace them with
water-tight conduit adapters or similar connectors. Failure to
comply with this requirement will void the Badger Meter, Inc.
warranty. To access the electrical connection, remove the cover
of the amplifier by loosening the four (4) mounting screws.
For all wiring, use 18 or 20 Awg wire.
• ThisconnectionshownaboveisforBatchPanelsthatrequirea115VAChotpulseformetersignals.
• ItisrecommendedthattheBatchPanelManufacturerbeconsultedtoconrmtherequiredpulsesignal.
• Fora115VACneutralpulsesignaltoBatchPanelsimplytakeT-2Jumperto115neutralpowersupply.
POWER SUPPLY CONNECTION
Ground
Neutral 115 VAC
Hot 115 VAC
Ground
Neutral 115 VAC
Hot 115 VAC
CONNECTING MODEL 7500P TO 110 VAC FROM BATCH CONTROL PANEL POWER SUPPLY.
(TYPICAL CONCRETE BATCH PANEL)