Badger® Series 330 Installation & Operation Manual Programmable - Set-Point Relay Control N.O. ComA N.C. ComB Hi Com Low ® Industrial AC Load/DC + AC Common/DC - Power Out (+) Input (-) Shield Model: 330 SN# 0000000 Output ® DIC Comm. Port 872039 BadgerMeter, Inc. Rev.
The Badger® Series 330 is a compact, programmable relay control capable of converting the signal from a Badger Meter flow sensor into a flow switch. any panel using double sided adhesive tape or by attaching fasteners through the holes in the mounting flanges of the unit. With an onboard microcontroller and digital circuitry, the Badger Series 330 is programmed from a Windows® based computer program.
Note: Included with every Series 330 is a Series 330IK kit containing a screw, lock washer and ground lead to connect the Series 330 to earth ground. This will help prevent electrical interference from affecting the Series 330’s normal operation. AC or DC Power Supply 3) If sensor is a Badger Series 4000 then: 1) Connect the red wire of the Series 4000 to Power on the Series 330. 2) Connect the black wire of the Series 4000 to the Sensor (-) on the Series 330.
Communications Cable Wiring Field calibration requires a Badger Meter Series A330 Programming kit (consisting of a custom cable and software) and a PC running Windows® XP or Vista. In order to program, the Badger® Series 330 must be connected to power, and the Series A301 cable must be connected to the Series 330 Com port connector and an available 9-pin Com port on a computer. Note: The Badger Meter Series A301 Cable will work with all Series 300 products.
SPECIFICATIONS Power Power Supply Options 12-36 VDC (+/- 10%) 12-26 VAC (+/- 10%) Current Draw 60 mA @ 12 VDC Flow Sensor Input All Sensors Excitation voltage 3 wire sensors: 9.1 VDC 500Ω source impedance Pulse Type Sensors Signal Amplitude 2.
FACTORY DEFAULTS Default Values Serial Number n/a Version n/a Sensor Type K= 1 Offset= 0 Flow Rate Units gpm Alarm Type off High Alarm Latched off High Alarm Set Point 120 High Alarm Set Point Delay 6 Pulse 5 High Alarm Release Point 110 High Alarm Release Point Delay 10 Low Alarm Latched off Low Alarm Set Point 10 Low Alarm Set Point Delay 5 Low Alarm Release Point 15 Low Alarm Release Point Delay 10 Filter Coeff 2 Customer Values
(This page intentionally left blank.
(This page intentionally left blank) Badger® and Data Industrial® are registered trademarks of Badger Meter Inc. Windows® is a registered trademark of Microsoft Corporation. Due to continuous research, product improvements and enhancements, Badger Meter reserves the right to change product or system specifications without notice, except to the extent an outstanding contractual obligation exists. BadgerMeter, Inc. Please see our website at www.badgermeter.com for specific contacts.